Literature DB >> 17106140

Efficacy and safety of controlled-release isosorbide-5-mononitrate in Japanese patients with stable effort angina pectoris.

Kazunori Shimada1, Satoshi Sunayama, Kaoru Nakazato, Hiroyuki Satoh, Yoshiki Kusama, Kiyoshi Kawakubo, Hiroyuki Daida.   

Abstract

A new controlled-release isosorbide-5-mononitrate (CR-ISMN) preparation has been developed to meet the requirement for a low nitrate concentration interval in order to avoid nitrate tolerance. We conducted a randomized, double-blind, placebo-controlled study in 31 Japanese patients with stable effort angina pectoris to investigate the efficacy and safety of CR-ISMN. Patients were randomly assigned to either CR-ISMN (40 mg once daily) or placebo groups for 2 weeks after two consecutive symptom-limited treadmill exercise tests using the Bruce protocol to ascertain the reproducibility of exercise tolerance during the placebo run-in period. Exercise tests were repeated at 5, 12, and 24 hours after administration on the final day. No significant difference in exercise time to moderate angina was identified between the CR-ISMN and placebo groups at 5, 12, or 24 hours after administration. However, the changes in exercise were prolonged at 5 hours but not shortened at 24 hours in the CR-ISMN group. The results of subgroup analysis suggested that the concomitant use of insulin might lead to confounding results. Although headache was the most frequent adverse effect in the CR-ISMN group, all symptoms were mild and at self-limiting levels. The plasma concentrations of CR-ISMN maintained therapeutic levels at 5 and 12 hours, and gradually decreased to less than the minimum therapeutic concentration (100 ng/mL) at 24 hours after administration. This study demonstrates that CR-ISMN improves exercise tolerance during the daytime and is well-tolerated in Japanese patients with stable effort angina pectoris without increasing the number of serious adverse effects.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17106140     DOI: 10.1536/ihj.47.695

Source DB:  PubMed          Journal:  Int Heart J        ISSN: 1349-2365            Impact factor:   1.862


  1 in total

1.  Determination of Isosorbide-5-Mononitrate in Human Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Bioequivalence Study.

Authors:  Yinping Zhou; Aijing Liu; Ranran Jia; Mengyi Wu; Ni Wu; Chunyan Liu; Zhihui Han; Haitang Hu; Hongyun Wang; Qing He
Journal:  J Anal Methods Chem       Date:  2020-07-17       Impact factor: 2.193

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.