Intra-operative evaluation of cementless hip implant stability: a prototype device based on vibration analysis.

Maurizio Lannocca1, Elena Varini, Angelo Cappello, Luca Cristofolini, Ewa Bialoblocka.   

Abstract

Cementless implants are mechanically stabilized during surgery by a press-fitting procedure. Good initial stability is crucial to avoid stem loosening and bone cracking, therefore, the surgeon must achieve optimal press-fitting. A possible approach to solve this problem and assist the surgeon in achieving the optimal compromise, involves the use of vibration analysis. The present study aimed to design and test a prototype device able to evaluate the primary mechanical stability of a cementless prosthesis, based on vibration analysis. In particular, the goal was to discriminate between stable and quasi-stable implants; thus the stem-bone system was assumed to be linear in both cases. For that reason, it was decided to study the frequency responses of the system, instead of the harmonic distortion. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The most sensitive parameter to stability was the shift in resonance frequency of the stem-bone system, which was highly correlated with residual micromotion on all four specimens.

Mesh:

Year:  2006        PMID: 17101289     DOI: 10.1016/j.medengphy.2006.09.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  9 in total

1.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

2.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

3.  Knee Implant Loosening Detection: A Vibration Analysis Investigation.

Authors:  Arash Arami; Jean-Romain Delaloye; Hossein Rouhani; Brigitte M Jolles; Kamiar Aminian
Journal:  Ann Biomed Eng       Date:  2017-10-24       Impact factor: 3.934

4.  Acoustic pattern evaluation during cementless hip arthroplasty surgery may be a new method for predicting complications.

Authors:  Itaru Morohashi; Hideaki Iwase; Akio Kanda; Taichi Sato; Yasuhiro Homma; Atsuhiko Mogami; Osamu Obayashi; Kazuo Kaneko
Journal:  SICOT J       Date:  2017-02-13

Review 5.  Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants.

Authors:  João Henrique Cachão; Marco P Soares Dos Santos; Rodrigo Bernardo; António Ramos; Rainer Bader; Jorge A F Ferreira; António Torres Marques; José A O Simões
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

6.  Experimental Investigation of Vibration Analysis on Implant Stability for a Novel Implant Design.

Authors:  Shouxun Lu; Benjamin Steven Vien; Matthias Russ; Mark Fitzgerald; Wing Kong Chiu
Journal:  Sensors (Basel)       Date:  2022-02-21       Impact factor: 3.576

7.  Multiscale Sensing of Bone-Implant Loosening for Multifunctional Smart Bone Implants: Using Capacitive Technologies for Precision Controllability.

Authors:  Inês Peres; Pedro Rolo; Jorge A F Ferreira; Susana C Pinto; Paula A A P Marques; António Ramos; Marco P Soares Dos Santos
Journal:  Sensors (Basel)       Date:  2022-03-25       Impact factor: 3.576

8.  Investigation of a passive sensor array for diagnosis of loosening of endoprosthetic implants.

Authors:  Cathérine Ruther; Christian Schulze; Andrea Boehme; Hannes Nierath; Hartmut Ewald; Wolfram Mittelmeier; Rainer Bader; Daniel Kluess
Journal:  Sensors (Basel)       Date:  2012-12-20       Impact factor: 3.576

9.  In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses.

Authors:  Leonard C Pastrav; Siegfried Vn Jaecques; Ilse Jonkers; Georges Van der Perre; Michiel Mulier
Journal:  J Orthop Surg Res       Date:  2009-04-09       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.