Literature DB >> 17100742

Immediately loaded titanium implants with a porous anodized surface with at least 36 months of follow-up.

Marco Degidi1, Vittoria Perrotti, Adriano Piattelli.   

Abstract

BACKGROUND: Results from some studies clearly suggest that immediate loading can achieve equal success rates as those found in delayed or unloaded implants. There is still a lack of knowledge about the role of surface oxide properties during the peri-implant bone healing processes.
PURPOSE: The aim of this study was a clinical follow-up study of immediately loaded implants with a porous anodized surface.
MATERIALS AND METHODS: A total of 142 TiUnite (Nobel Biocare, Göteborg, Sweden) implants were inserted from January to September 2001. All implants have been used in fixed restorations. Fifty implants were inserted in completely edentulous mandibles, and 69 implants were inserted in completely edentulous maxillae. All 119 implants were subjected to immediate functional loading (IFL) (immediate restoration with full occlusal contact). The other 23 implants, inserted in 12 patients, underwent immediate nonfunctional loading (INFL) (immediate restoration without occlusal contact) in different anatomical configurations (single tooth, small bridges in the anterior mandible, anterior maxilla, and posterior maxilla). All 142 implants have been followed for at least 3 years.
RESULTS: All implants appeared to be osseointegrated from a clinical and radiographic point of view. No failures were observed in the IFL and INFL groups. The implant success was 100%. The mean marginal bone loss was 0.8 and 1.0 mm at 12 and 36 months, respectively.
CONCLUSION: Implants with a porous anodized surface appear to work well under an immediate loading state in the long term.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17100742     DOI: 10.1111/j.1708-8208.2006.00008.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  4 in total

1.  Evaluation of crestal bone loss and stability of immediate functional loading versus immediate non-functional loading of single-mandibular posterior implants: A pilot randomized controlled clinical trial.

Authors:  Satyanarayana Raju Mantena; G Sivagami; Sruthima Nvs Gottumukkala
Journal:  Dent Res J (Isfahan)       Date:  2014-09

2.  Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill.

Authors:  Sergio Alexandre Gehrke; Raphaél Bettach; Jaime Sardá Aramburú Júnior; Juan Carlos Prados-Frutos; Massimo Del Fabbro; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2018-04-11       Impact factor: 3.411

3.  Dental implants inserted in native bone: Cases series analyses.

Authors:  Riccardo Guidi; Alessandro Viscioni; Frencesco Dattola; Francesco Carinci
Journal:  Dent Res J (Isfahan)       Date:  2012-12

4.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.