Does the accuracy of single reading with CAD (computer-aided detection) compare with that of double reading?: A review of the literature.

R L Bennett1, R G Blanks, S M Moss.   

Abstract

AIM: To examine current evidence to determine whether the accuracy of single reading with computed-aided detection (CAD) compares with that of double reading.
METHODS: We performed a literature review to identify studies where both protocols had been investigated and compared. We identified eight studies that compared single reading with CAD against double reading, of which six reported on comparisons of both sensitivity and specificity.
RESULTS: Of the six studies identified, three showed no differences in either sensitivity or specificity. One showed single reading with CAD had a higher sensitivity at the same specificity, another that single reading with CAD had a higher specificity at the same sensitivity. However, one study, in a real-life setting, showed that single reading with CAD had a higher sensitivity but a lower specificity.
CONCLUSION: As the majority of the studies were not in a real-life setting, used test sets, lacked sufficient training in the use of CAD and simulated double reading (using a protocol of recall if one suggests), current evidence is therefore limited as to the accuracy, in terms of sensitivity and specificity, of single reading with CAD in comparison with the most common practice in the UK of double reading using a protocol of consensus or arbitration.

Mesh:

Year:  2006        PMID: 17097423     DOI: 10.1016/j.crad.2006.09.006

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  4 in total

Review 1.  [Mammography screening in Germany].

Authors:  S Diekmann; F Diekmann
Journal:  Radiologe       Date:  2008-01       Impact factor: 0.635

Review 2.  Needs assessment for next generation computer-aided mammography reference image databases and evaluation studies.

Authors:  Alexander Horsch; Alexander Hapfelmeier; Matthias Elter
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-03-30       Impact factor: 2.924

3.  Computer-assisted diagnosis (CAD) in mammography: comparison of diagnostic accuracy of a new algorithm (Cyclopus, Medicad) with two commercial systems.

Authors:  S Ciatto; D Cascio; F Fauci; R Magro; G Raso; R Ienzi; F Martinelli; M Vasile Simone
Journal:  Radiol Med       Date:  2009-05-14       Impact factor: 3.469

Review 4.  Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review.

Authors:  Edward Azavedo; Sophia Zackrisson; Ingegerd Mejàre; Marianne Heibert Arnlind
Journal:  BMC Med Imaging       Date:  2012-07-24       Impact factor: 1.930

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.