Literature DB >> 17096392

DENSE and HARP: two views on the same technique of phase-based strain imaging.

Joost P A Kuijer1, Mark B M Hofman, Jaco J M Zwanenburg, J Tim Marcus, Albert C van Rossum, Rob M Heethaar.   

Abstract

PURPOSE: To discuss differences between displacement encoding with stimulated echoes (DENSE) and the harmonic phase (HARP) in imaging and reconstruction strategies.
MATERIALS AND METHODS: HARP and DENSE are presented in their historical context: while the HARP method was developed from the framework of myocardial tagging, DENSE arose from the framework of stimulated echo and displacement encoding using bipolar gradients. Both techniques have evolved since their introduction, thereby becoming more similar over time and losing their distinct features. Newly introduced improvements have successfully been applied in both methods. Differences between both methods are discussed point by point.
RESULTS: From this discussion it follows that almost all apparent differences are in fact nonexistent.
CONCLUSION: In the literature, both techniques are still regarded as distinctly different techniques, where a more general treatment of the technique is justified. Once it is realized that both frameworks are easily merged, the benefits are 1) less confusion about the (dis)advantages of either technique, and 2) understanding of phase-based strain imaging that is more general than HARP or DENSE alone. (c) 2006 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2006        PMID: 17096392     DOI: 10.1002/jmri.20749

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  14 in total

Review 1.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

2.  Three-dimensional regional strain computation method with displacement encoding with stimulated echoes (DENSE) in non-ischemic, non-valvular dilated cardiomyopathy patients and healthy subjects validated by tagged MRI.

Authors:  Julia Kar; Andrew K Knutsen; Brian P Cupps; Xiaodong Zhong; Michael K Pasque
Journal:  J Magn Reson Imaging       Date:  2014-02-07       Impact factor: 4.813

3.  Heterogeneity of intramural function in hypertrophic cardiomyopathy: mechanistic insights from MRI late gadolinium enhancement and high-resolution displacement encoding with stimulated echoes strain maps.

Authors:  Anthony H Aletras; Gauri S Tilak; Li-Yueh Hsu; Andrew E Arai
Journal:  Circ Cardiovasc Imaging       Date:  2011-05-16       Impact factor: 7.792

4.  3D left ventricular strain from unwrapped harmonic phase measurements.

Authors:  Bharath Ambale Venkatesh; Himanshu Gupta; Steven G Lloyd; Louis Dell 'Italia; Thomas S Denney
Journal:  J Magn Reson Imaging       Date:  2010-04       Impact factor: 4.813

5.  TRUHARP: SINGLE BREATH-HOLD MRI FOR HIGH RESOLUTION CARDIAC MOTION AND STRAIN QUANTIFICATION.

Authors:  Harsh K Agarwal; Khaled Z Abd-Elmoniem; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-06-28

6.  Intermittently tagged real-time MRI reveals internal tongue motion during speech production.

Authors:  Weiyi Chen; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

7.  A new methodology for multiscale myocardial deformation and strain analysis based on tagging MRI.

Authors:  Luc Florack; Hans van Assen
Journal:  Int J Biomed Imaging       Date:  2010-03-01

8.  Motion-guided segmentation for cine DENSE MRI.

Authors:  Bruce S Spottiswoode; Xiaodong Zhong; Christine H Lorenz; Bongani M Mayosi; Ernesta M Meintjes; Frederick H Epstein
Journal:  Med Image Anal       Date:  2008-07-09       Impact factor: 8.545

9.  Relationship between cardiovascular risk factors and myocardial strain values of both ventricles in asymptomatic Asian subjects: measurement using cardiovascular magnetic resonance tissue tracking.

Authors:  Ji-Won Hwang; Min Jae Cha; Sung Mok Kim; Yiseul Kim; Yeon Hyeon Choe
Journal:  Int J Cardiovasc Imaging       Date:  2018-07-17       Impact factor: 2.357

Review 10.  Quantification in cardiac MRI: advances in image acquisition and processing.

Authors:  Anil K Attili; Andreas Schuster; Eike Nagel; Johan H C Reiber; Rob J van der Geest
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

View more