PURPOSE: To perform a meta-analysis of diagnostic studies regarding the accuracy of antigranulocyte scintigraphy (AGS) with monoclonal antibodies in the identification of prosthesis infection after total hip or knee arthroplasty. MATERIALS AND METHODS: PubMed and EMBASE searches were conducted for the identification of relevant studies. Data on the diagnostic performance of AGS with monoclonal antibodies were combined quantitatively across eligible studies, and the overall sensitivity and specificity, along with summary receiver operating characteristic (ROC) curves and likelihood ratios (LRs), were estimated. The above parameters were evaluated for all patients and for various subgroups among the eligible studies. The reference standard used in the individual studies was accepted. RESULTS: Thirteen eligible studies on nonoverlapping patient groups were included in the meta-analysis; there was a total sample size of 522 implants. The independent random effects summary estimates of sensitivity and specificity were 83% and 80%, respectively. The summary ROC curve estimate for weighted analysis was a sensitivity of 90% for a specificity of 80%. LR syntheses gave a weighted positive LR of 3.99 (95% confidence interval [CI]: 3.13, 5.09) and a weighted negative LR of 0.22 (95% CI: 0.15, 0.34); there was no statistically significant between-study heterogeneity for either metric. Various subgroup analyses did not reveal any statistically significant differences. CONCLUSION: AGS with monoclonal antibodies had a reasonably high discriminating ability to identify prosthesis infection in patients who underwent total joint arthroplasty. Copyright (c) RSNA, 2006.
PURPOSE: To perform a meta-analysis of diagnostic studies regarding the accuracy of antigranulocyte scintigraphy (AGS) with monoclonal antibodies in the identification of prosthesis infection after total hip or knee arthroplasty. MATERIALS AND METHODS: PubMed and EMBASE searches were conducted for the identification of relevant studies. Data on the diagnostic performance of AGS with monoclonal antibodies were combined quantitatively across eligible studies, and the overall sensitivity and specificity, along with summary receiver operating characteristic (ROC) curves and likelihood ratios (LRs), were estimated. The above parameters were evaluated for all patients and for various subgroups among the eligible studies. The reference standard used in the individual studies was accepted. RESULTS: Thirteen eligible studies on nonoverlapping patient groups were included in the meta-analysis; there was a total sample size of 522 implants. The independent random effects summary estimates of sensitivity and specificity were 83% and 80%, respectively. The summary ROC curve estimate for weighted analysis was a sensitivity of 90% for a specificity of 80%. LR syntheses gave a weighted positive LR of 3.99 (95% confidence interval [CI]: 3.13, 5.09) and a weighted negative LR of 0.22 (95% CI: 0.15, 0.34); there was no statistically significant between-study heterogeneity for either metric. Various subgroup analyses did not reveal any statistically significant differences. CONCLUSION:AGS with monoclonal antibodies had a reasonably high discriminating ability to identify prosthesis infection in patients who underwent total joint arthroplasty. Copyright (c) RSNA, 2006.
Authors: Filip Gemmel; Hans Van den Wyngaert; Charito Love; M M Welling; Paul Gemmel; Christopher J Palestro Journal: Eur J Nucl Med Mol Imaging Date: 2012-02-24 Impact factor: 9.236
Authors: Vera Graute; Markus Feist; Sebastian Lehner; Alexander Haug; Peter Ernst Müller; Peter Bartenstein; Marcus Hacker Journal: Eur J Nucl Med Mol Imaging Date: 2010-03-23 Impact factor: 9.236
Authors: Luca Maria Sconfienza; Alberto Signore; Victor Cassar-Pullicino; Maria Adriana Cataldo; Olivier Gheysens; Olivier Borens; Andrej Trampuz; Klaus Wörtler; Nicola Petrosillo; Heinz Winkler; Filip M H M Vanhoenacker; Paul C Jutte; Andor W J M Glaudemans Journal: Eur Radiol Date: 2019-06-27 Impact factor: 5.315
Authors: Sufian S Ahmad; Ahmed Shaker; Mo Saffarini; Antonia F Chen; Michael T Hirschmann; Sandro Kohl Journal: Knee Surg Sports Traumatol Arthrosc Date: 2016-07-05 Impact factor: 4.342