Calibration of multiple LDR brachytherapy sources.

Larry A DeWerd1, John A Micka, Shannon M Holmes, Tim D Bohm.   

Abstract

A trend is underway toward the use of prepackaged low dose rate brachytherapy sources, which come in the form of strands, coiled line sources, preloaded needles, and sterile cartridge packs. Since the medical physicist is responsible for verification of source strength prior to patient treatment, development of prepackaged source strength verification methods is needed. Existing guidelines are reviewed to establish the situation that medical physicists find with respect to prepackaged sources. This investigation presents an experimental evaluation of the effect of some of these multiseed geometries on source strength measurements. Multiseed strands and coils, whether 125I, 103Pd, or 192Ir can be measured in a chamber with a long, sensitive axial length with a uniform response. Sterile seed cartridge packs can also be measured but require a correction factor to be applied. Sources in needles, however, cannot be measured in the needle since there is too great a variation in needle composition and needle tolerance thickness. Removing these seeds from the needle into a sterile measurement insert, which maintains sterility is a practical source strength verification method, similar to those done for multiple seed configurations in a well chamber with adequate axial uniformity. Values are compared with individual air kerma strength calibrations, and correction factors, are presented' where needed. In each case, care must be taken to maintain sterility as multiple seeds are measured in well chamber inserts.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17089845     DOI: 10.1118/1.2348765

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Dosimetric characterization of a new directional low-dose rate brachytherapy source.

Authors:  Manik Aima; Larry A DeWerd; Michael G Mitch; Clifford G Hammer; Wesley S Culberson
Journal:  Med Phys       Date:  2018-05-24       Impact factor: 4.071

2.  Source strength assay of iodine-125 seeds sealed within sterile packaging.

Authors:  Yuki Otani; Takahiro Yamada; Shingo Kato; Naoto Shikama; Kazuto Funakoshi; Isao Kuroda; Hodaka Numasaki; Takayuki Nose; Takushi Dokiya; Masahiko Oguchi
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.