Literature DB >> 17089297

[Allergic reaction to components of bone cement after total knee arthroplasty].

A Schuh1, P Thomas, R Reinhold, U Holzwarth, G Zeiler, V Mahler.   

Abstract

There are many reports about allergic reactions in association with total hip or knee arthroplasty. While most studies focus on allergic reactions to metallic components, only few reports exist about reactions to bone cement or its ingredients. We report about a patient who developed eczema at the knee and the lower leg one year after cemented TKR. Patch testing showed as potential causes contact allergic reactions to nickel and benzoylperoxide, an ingredient of the here used bone cement. The local and temporal association between onset of eczema and knee arthroplasty suggests a causal link. Benzoylperoxide as potential contact allergen in bone cement is so far almost neglected. The development of extended testing procedures and data collection should provide further information and better care of these patients. The development of special bone cements for patients with allergic diathesis is requested.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17089297     DOI: 10.1055/s-2006-949533

Source DB:  PubMed          Journal:  Zentralbl Chir        ISSN: 0044-409X            Impact factor:   0.942


  9 in total

1.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

Review 2.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

Review 3.  [The importance of wear couples for younger endoprosthesis patients].

Authors:  J Kircher; P Bergschmidt; R Bader; D Kluess; E Besser-Mahuzir; A Leder; W Mittelmeier
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

4.  [Preclinical evaluation of coated knee implants for allergic patients].

Authors:  J Reich; L Hovy; H-L Lindenmaier; R Zeller; J Schwiesau; P Thomas; T M Grupp
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

5.  [Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German association of orthopedics and orthopedic surgery), DKG (German contact dermatitis research group) and dgaki (German society for allergology and clinical immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Orthopade       Date:  2008-01       Impact factor: 1.087

6.  [Recurrent effusion and granulomatous synovitis following total knee arthroplasty in association with latex allergy].

Authors:  A Schuh; P Thomas; W Hönle; T Schmickal
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

Review 7.  [Allergy to bone cement components].

Authors:  P Thomas; A Schuh; R Eben; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

8.  [Implant allergy register--a first report].

Authors:  R Eben; R Walk; B Summer; S Maier; M Thomsen; P Thomas
Journal:  Orthopade       Date:  2009-06       Impact factor: 1.087

9.  [Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Hautarzt       Date:  2008-03       Impact factor: 1.198

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.