Literature DB >> 17088461

Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation.

Dieter Ropers1, Falk-Karsten Pohle, Axel Kuettner, Tobias Pflederer, Katharina Anders, Werner G Daniel, Werner Bautz, Ulrich Baum, Stephan Achenbach.   

Abstract

BACKGROUND: Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. METHODS AND
RESULTS: Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts) were investigated by MDCT (0.6-mm collimation, 32 detector rows, 2 focal points, 330-ms rotation) 9 to 252 months (mean, 106 months) after surgery. CABG and all native coronary arteries with a diameter of > 1.5 mm were evaluated for the presence of significant stenoses (> or = 50% diameter reduction). Results were compared with quantitative coronary angiography. By MDCT, all CABG were evaluable and were correctly classified as occluded (n=38) or patent (n=100). Sensitivity for stenosis detection in patent grafts was 100% (16/16) with a specificity of 94% (79/84). For the per-segment evaluation of native coronary arteries and distal runoff vessels, sensitivity in evaluable segments (91%) was 86% (87/101) with a specificity of 76% (354/465). If evaluation was restricted to nongrafted arteries and distal runoff vessels, sensitivity was 86% (38/44) with a specificity of 90% (302/334). On a per-patient basis, classifying patients with at least 1 detected stenosis in a CABG, a distal runoff vessel, or a nongrafted artery or with at least 1 unevaluable segment as "positive," MDCT yielded a sensitivity of 97% (35/36) and specificity of 86% (12/14).
CONCLUSIONS: We found that 64-slice MDCT permits the evaluation of bypass grafts and the assessment of the native coronary arteries for the presence of stenosis.

Entities:  

Mesh:

Year:  2006        PMID: 17088461     DOI: 10.1161/CIRCULATIONAHA.106.631051

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  43 in total

1.  Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM).

Authors:  E di Cesare; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; L Natale; A Romagnoli; V Russo; F Sardanelli; F Cademartiri
Journal:  Radiol Med       Date:  2012-04-01       Impact factor: 3.469

2.  Diagnostic accuracy of 64-slice multidetector computed tomography in evaluation of post-coronary artery bypass grafts in correlation with invasive coronary angiography.

Authors:  Rajani Gorantla; J S N Murthy; T R Muralidharan; Rupesh Mandava; Bhawna Dev; Harsha Chandaga; R Rajeswaran; J D Roy Santosham; Santhosh Joseph
Journal:  Indian Heart J       Date:  2012 May-Jun

3.  Imaging study on the optic canal using sixty four-slice spiral computed tomography.

Authors:  Peng-Fei Jiang; Xiu-Yu Dai; Yongbin Lv; Shaoyi Liu; Xiao-Yan Mu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

Review 4.  Comprehensive cardiac CT study: evaluation of coronary arteries, left ventricular function, and myocardial perfusion--is it possible?

Authors:  Ricardo C Cury; Koen Nieman; Michael D Shapiro; Khurram Nasir; Roberto C Cury; Thomas J Brady
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

Review 5.  Current and upcoming roles of CT and MRI in clinical cardiac imagery.

Authors:  Scott Beach; Mushabbar A Syed
Journal:  Curr Cardiol Rep       Date:  2007-09       Impact factor: 2.931

Review 6.  History of cardiac computed tomography: single to 320-detector row multislice computed tomography.

Authors:  Gregory S Hurlock; Hiroshi Higashino; Teruhito Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2009-01-15       Impact factor: 2.357

7.  64 slice computed tomography-a novel diagnostic method for evaluation of patients after coronary artery bypass grafts.

Authors:  S Balashankar Gomathi; P Nandhini; R Ravikumar; S Mullasari Ajit
Journal:  Indian Heart J       Date:  2012-03-26

8.  Coronary computed tomographic angiography: current and future uses.

Authors:  Birgit Kantor; Ronald S Kuzo; Thomas C Gerber
Journal:  Heart Metab       Date:  2007

Review 9.  Transitioning from 16-slice to 64-slice multidetector computed tomography for the assessment of coronary artery disease: are we really making progress?

Authors:  Razi Khan; Sapna Rawal; Mark J Eisenberg
Journal:  Can J Cardiol       Date:  2009-09       Impact factor: 5.223

Review 10.  Coronary artery bypass grafts and MDCT imaging: what to know and what to look for.

Authors:  Riccardo Marano; Carlo Liguori; Pierluigi Rinaldi; Maria Luigia Storto; Marco Angelo Politi; Giancarlo Savino; Lorenzo Bonomo
Journal:  Eur Radiol       Date:  2007-09-15       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.