Powered, air-purifying particulate respirator filter penetration by a DOP aerosol.

Stephen Martin1, Ernest Moyer, Paul Jensen.   

Abstract

In 1995, new certification requirements for all nonpowered, air-purifying particulate filter respirators were put in place when 42 CFR 84 replaced 30 CFR 11. However, the certification requirements for all other classes of respirators, including powered air-purifying respirators (PAPRs), were transferred to 42 CFR 84 from 30 CFR 11 without major changes. Since the inception of 42 CFR 84, researchers have learned that the efficiency of electrostatic filter media, in contrast with mechanical filter media, can be rapidly degraded by oil aerosols. Further, confusion may exist among respirator users, since electrostatic PAPR filters have the same magenta color assigned to high-efficiency filters for nonpowered particulate respirators that have been tested and certified for use against oil aerosols (i.e., P100 filters). Users may expect that the magenta color of certified PAPR filters indicates suitability for use against oil aerosols. This may not be the case. To illustrate the potential degradation of electrostatic PAPR filters, new filters certified under 42 CFR 84 were tested using a TSI model 8122 Automated Respirator Tester against charged and neutralized DOP aerosols with intermittent loading schedules. The performance of a magenta-colored electrostatic PAPR filter--one for which the manufacturer's user instructions appropriately indicates is not suitable for use in oily environments--was compared with the performance of several mechanical PAPR filters. In tests against both DOP aerosols, the electrostatic PAPR filter showed a significant decrease in performance at DOP loadings exceeding 400 mg, whereas mechanical filters showed no significant change in the performance except at extremely high loadings. The decreased performance of the electrostatic PAPR filter was found to be significantly greater when tested against a neutralized DOP aerosol when compared with a charged DOP aerosol. While laboratory tests show that the filtration efficiency of this electrostatic PAPR filter degrades with exposure to DOP aerosol, the observed laboratory degradation may or may not affect workplace performance, as similar degradation has not been verified in workplace studies. Based on these laboratory results, a proposed method for evaluating high-efficiency PAPR filters is presented. This proposed method would ensure that high-efficiency PAPR filters (> or = 99.97% efficient and magenta in color) meet critical performance criteria when loaded.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17086666     DOI: 10.1080/15459620600953995

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  2 in total

1.  Development of a Manikin-Based Performance Evaluation Method for Loose-Fitting Powered Air-Purifying Respirators.

Authors:  Mike Bergman; Rohan Basu; Zhipeng Lei; George Niezgoda; Ziqing Zhuang
Journal:  J Int Soc Respir Prot       Date:  2017

2.  Evaluation of performance loss of paraffin oil loaded filtering facepieces.

Authors:  Francesca Tombolini; Stefano Listrani; Antonella Campopiano; Carmela Plebani
Journal:  Ind Health       Date:  2016       Impact factor: 2.179

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.