Literature DB >> 17084722

Radiolabeled and near-infrared fluorescent fibrinogen derivatives create a system for the identification and repair of obscure gastrointestinal bleeding.

Shunsuke Ohnishi1, Evan S Garfein, Seth J Karp, John V Frangioni.   

Abstract

BACKGROUND: Gastrointesintal hemorrhage is often difficult to localize. A test that does not depend on active bleeding might prove clinically useful. We tested 2 novel fibrinogen (FBG)-based contrast agents for their ability to localize gastrointestinal (GI) hemorrhage after bleeding stopped. 125I-FBG permits gamma ray-based preoperative or intraoperative scanning, and near-infrared (NIR) flourescent FBG (FBG800) permits real-time intraoperative visualization of active clot.
METHODS: Bovine FBG was radiolabeled with 125I or conjugated to the NIR fluorophore CW800. Sites of bleeding were created by gastrotomy, mucosal resection of the stomach, or laceration of a mesenteric vessel; then 1.7 mg/kg FBG800 or 15 microCi/kg 125I-FBG was injected intravenously into mice, rabbits, or pigs 30 minutes before or after injury. Sites of active clot were quantified by using gamma counting and were also imaged by using invisible NIR light intraoperatively, for up to 3 hours postinjection.
RESULTS: After an injection of either 125I-FBG or FBG800, sites of prior bleeding could be identified in the absence of active bleeding. Blood clearance was such that a signal-to-background ratio of 2.0 or greater could be achieved within 20 minutes after injection. A similarly labeled human serum albumin did not accumulate at any site, with an SBR of 1.0 or less.
CONCLUSIONS: Both radiolabeled (preoperative gamma scanning) and NIR fluorescent (intraoperative real-time imaging) FBG can be used in experimental situations to identify the location of prior bleeding in the absence of active bleeding. Taken together, these contrast agents create a system for the identification and control of obscure GI bleeding.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17084722      PMCID: PMC2474709          DOI: 10.1016/j.surg.2006.03.027

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  18 in total

Review 1.  Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents.

Authors:  Eva M Sevick-Muraca; Jessica P Houston; Michael Gurfinkel
Journal:  Curr Opin Chem Biol       Date:  2002-10       Impact factor: 8.822

Review 2.  Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging.

Authors:  Vasilis Ntziachristos; Christoph Bremer; Ralph Weissleder
Journal:  Eur Radiol       Date:  2002-07-19       Impact factor: 5.315

Review 3.  In vivo near-infrared fluorescence imaging.

Authors:  John V Frangioni
Journal:  Curr Opin Chem Biol       Date:  2003-10       Impact factor: 8.822

Review 4.  Human fibrinogen: anticipating a 3-dimensional structure.

Authors:  R F Doolittle; S J Everse; G Spraggon
Journal:  FASEB J       Date:  1996-11       Impact factor: 5.191

5.  Gastrointestinal hemorrhage. II. Angiographic diagnosis and control.

Authors:  S Baum; C A Athanasoulis; A C Waltman; E J Ring
Journal:  Adv Surg       Date:  1973

6.  Extraction, radioiodination, and in vivo catabolism of equine fibrinogen.

Authors:  C P Coyne; W J Hornof; A B Kelly; T R O'Brien; S J DeNardo
Journal:  Am J Vet Res       Date:  1985-12       Impact factor: 1.156

Review 7.  The blood coagulation system as a molecular machine.

Authors:  Henri M H Spronk; José W P Govers-Riemslag; Hugo ten Cate
Journal:  Bioessays       Date:  2003-12       Impact factor: 4.345

8.  99mTc RBC scintigraphy: correlation of gastrointestinal bleeding rates with scintigraphic findings.

Authors:  R Smith; D J Copely; F H Bolen
Journal:  AJR Am J Roentgenol       Date:  1987-05       Impact factor: 3.959

9.  Scintigraphic methods for detecting vascular thrombus.

Authors:  L C Knight
Journal:  J Nucl Med       Date:  1993-03       Impact factor: 10.057

10.  An operational near-infrared fluorescence imaging system prototype for large animal surgery.

Authors:  A M De Grand; J V Frangioni
Journal:  Technol Cancer Res Treat       Date:  2003-12
View more
  3 in total

1.  Targeted zwitterionic near-infrared fluorophores for improved optical imaging.

Authors:  Hak Soo Choi; Summer L Gibbs; Jeong Heon Lee; Soon Hee Kim; Yoshitomo Ashitate; Fangbing Liu; Hoon Hyun; GwangLi Park; Yang Xie; Soochan Bae; Maged Henary; John V Frangioni
Journal:  Nat Biotechnol       Date:  2013-01-06       Impact factor: 54.908

2.  Real-time intraoperative assessment of the extrahepatic bile ducts in rats and pigs using invisible near-infrared fluorescent light.

Authors:  Eiichi Tanaka; Hak Soo Choi; Valerie Humblet; Shunsuke Ohnishi; Rita G Laurence; John V Frangioni
Journal:  Surgery       Date:  2008-05-27       Impact factor: 3.982

3.  The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in breast cancer sentinel lymph node mapping.

Authors:  Susan L Troyan; Vida Kianzad; Summer L Gibbs-Strauss; Sylvain Gioux; Aya Matsui; Rafiou Oketokoun; Long Ngo; Ali Khamene; Fred Azar; John V Frangioni
Journal:  Ann Surg Oncol       Date:  2009-07-07       Impact factor: 5.344

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.