Literature DB >> 17082331

Accuracy of three-dimensional measurements using cone-beam CT.

H M Pinsky1, S Dyda, R W Pinsky, K A Misch, D P Sarment.   

Abstract

OBJECTIVES: Lesions causing intraosseous defects in the head and neck region are difficult to diagnose using two-dimensional radiography, and three-dimensional (3D) data provided by CT is useful but often difficult to obtain. Recently, cone-beam CT (CBCT) was made available, with the potential to become a practical tool in dentistry. However, there is limited evidence to prove that defect volume can be determined accurately. Therefore, this in vitro validation study aimed at establishing whether linear and 3D CBCT, using volumetric measurements, is accurate for determining osseous defect sizes.
METHODS: Depth and diameter of simulated bone defects in (i) an acrylic block and (ii) a human mandible were blindly measured electronically by five examiners using CBCT. Linear measurements were compared with predetermined machined dimensions. Using software, volume extraction was performed by another examiner on the acrylic phantom and compared with known dimensions. Data were analysed using paired t-tests.
RESULTS: Using the acrylic block, mean width accuracy was -0.01 mm (+/- 0.02 SE) and mean height difference was -0.03 mm (+/- 0.01 SE; P > 0.05). For the human mandible, mean width accuracy was -0.07 mm (+/- 0.02 SE) and mean height accuracy was -0.27 mm (+/- 0.02 SE; P < 0.01). Volume accuracy was -6.9 mm3 (+/- 4 SE) for automated calculations and -2.3 mm3 (+/- 2.6 SE) for the manual measurements (P < 0.001).
CONCLUSIONS: CBCT has the potential to be an accurate, non-invasive, practical method to reliably determine osseous lesion size and volume. Further clinical validation will lead to a vast array of applications in oral and maxillofacial diagnosis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17082331     DOI: 10.1259/dmfr/20987648

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  68 in total

1.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

2.  A suggested technique for the application of the cone beam computed tomography periapical index.

Authors:  S Esposito; M Cardaropoli; E Cotti
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

Review 3.  Periodontal surgery in furcation-involved maxillary molars revisited--an introduction of guidelines for comprehensive treatment.

Authors:  Clemens Walter; Roland Weiger; Nicola Ursula Zitzmann
Journal:  Clin Oral Investig       Date:  2010-06-23       Impact factor: 3.573

4.  Classification of periodontal biotypes with the use of CBCT. A cross-sectional study.

Authors:  Maria Nikiforidou; Lazaros Tsalikis; Christos Angelopoulos; Georgios Menexes; Ioannis Vouros; Antonios Konstantinides
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

5.  Comparison of observer reliability of three-dimensional cephalometric landmark identification on subject images from Galileos and i-CAT cone beam CT.

Authors:  R A Katkar; C Kummet; D Dawson; L Moreno Uribe; V Allareddy; M Finkelstein; A Ruprecht
Journal:  Dentomaxillofac Radiol       Date:  2013-07-05       Impact factor: 2.419

Review 6.  Conventional radiography and cross-sectional imaging when planning dental implants in the anterior edentulous mandible to support an overdenture: a systematic review.

Authors:  A M Shelley; A-M Glenny; M Goodwin; P Brunton; K Horner
Journal:  Dentomaxillofac Radiol       Date:  2013-11-22       Impact factor: 2.419

7.  Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography.

Authors:  K Kamburoğlu; C Kiliç; T Ozen; S Horasan
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

8.  Radiographic volume analysis as a novel tool to determine nasopalatine duct cyst dimensions and its association with presenting symptoms and postoperative complications.

Authors:  Valerie G A Suter; Saman Warnakulasuriya; Peter A Reichart; Michael M Bornstein
Journal:  Clin Oral Investig       Date:  2015-01-13       Impact factor: 3.573

9.  CBCT-based bone quality assessment in decompression of large odontogenic cystic lesions.

Authors:  Ling Gao; Wenhao Ren; Shaoming Li; Jingjing Zheng; Lingfa Xue; Yaoxiang Xu; Qibo Wang; Jianzhong Song; Zhichao Dou; Minzhan Zhou; Wenlin Xiao; Keqian Zhi
Journal:  Oral Radiol       Date:  2018-02-14       Impact factor: 1.852

10.  Use of cone beam computed tomography in endodontics.

Authors:  William C Scarfe; Martin D Levin; David Gane; Allan G Farman
Journal:  Int J Dent       Date:  2010-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.