Literature DB >> 17081872

Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusis.

Dan Z Reinstein1, Richard C Rothman, Darren G Couch, Timothy J Archer.   

Abstract

We present a patient in whom a symmetrically round free cap occurred during laser in situ keratomileusis (LASIK), and flap repositioning was performed without laser ablation. A loss of 3 lines of best spectacle-corrected visual acuity (BSCVA), monocular diplopia, and topographic irregular astigmatism confirmed that the free cap orientation was incorrect. Two subsequent free cap rotations based on refraction failed to realign the free cap into its original position. Artemis 3-dimensional very high-frequency digital ultrasound analysis found the thickness profiles of the free cap and bed to be irregular and mismatched. The rotation required for anatomic realignment was determined by digitally generating a "lock and key" superimposition of the free cap and stromal bed thickness profiles. After Artemis-guided free cap rotation, the eye regained preoperative BSCVA and symmetrical corneal topography with a +0.50 diopter change in spherical equivalent.

Entities:  

Mesh:

Year:  2006        PMID: 17081872     DOI: 10.1016/j.jcrs.2006.03.013

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Extended scan depth optical coherence tomography for evaluating ocular surface shape.

Authors:  Meixiao Shen; Lele Cui; Ming Li; Dexi Zhu; Michael R Wang; Jianhua Wang
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

2.  Epithelial, stromal, and total corneal thickness in keratoconus: three-dimensional display with artemis very-high frequency digital ultrasound.

Authors:  Dan Z Reinstein; Marine Gobbe; Timothy J Archer; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2010-04-07       Impact factor: 3.573

3.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

4.  Epithelial thickness after hyperopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2010-08       Impact factor: 3.573

5.  Applications of epithelial thickness mapping in corneal refractive surgery.

Authors:  Dan Z Reinstein; Timothy J Archer; Ryan S Vida
Journal:  Saudi J Ophthalmol       Date:  2022-07-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.