Literature DB >> 17080876

Bond strength of resin-based restorations polymerized with different light-curing sources.

Paulo H P D'Alpino1, Linda Wang, Frederick A Rueggeberg, Nádia R Svizero, José C Pereira, David H Pashley, Ricardo M Carvalho.   

Abstract

PURPOSE: To evaluate the influence of different light-curing units on microtensile bond strength of resin composite restorations.
MATERIALS AND METHODS: Standardized Class I preparations (6.0 x 4.5 mm, 2.5 mm deep) were made in extracted human third molars after abrading the cusps. Resin was inserted in bulk using a 3M ESPE restorative system [Adper Single Bond (DBA)/ Filtek Z250 (RC)]. Both materials were polymerized using different light-curing units: QTH at 540 mW/cm(2) (XL 3000, 3M ESPE); LED at 750 mW/cm(2) (Elipar FreeLight2, 3M ESPE); PAC at 2130 mW/cm(2) (Arc Light II, Air Techniques). Nine different light combinations were developed to polymerize both DBA and RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Restored teeth were stored in distilled water for 24 h at 37 degrees C and then sectioned, yielding stick-shaped specimens with a bonded area of approximately 0.9 mm(2). Specimens were assessed in a testing machine at a crosshead speed of 1 mm/min. The results were analyzed using two-way ANOVA and Tukey's test at a pre-set alpha = 0.05.
RESULTS: The combinations PAC/QTH and QTH/QTH presented the highest bond strength values, and LED/QTH the lowest (p < 0.05). Significantly lower values were observed in combinations when the LED light was used to polymerize DBA compared to QTH and PAC lights, irrespective of the light source used to polymerize RC (p < 0.05). Same light combinations presented similar bond strength values.
CONCLUSIONS: Different light sources influence restoration bond strength. Bond strength is more dependent on the light source used for DBA than for curing RC.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17080876

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  2 in total

1.  An in vitro evaluation of shear bond strength of silorane and bis-GMA resin-based composite using different curing units.

Authors:  Manak Khosla; Neeraj Malhotra; Kundabala Mala
Journal:  J Conserv Dent       Date:  2012-07

2.  Influence of commercial adhesive with/without silane on the bond strength of resin-based composite repaired within twenty-four hours.

Authors:  Ker-Kong Chen; Jeng-Huey Chen; Ju-Hui Wu; Je-Kang Du
Journal:  J Dent Sci       Date:  2020-12-31       Impact factor: 2.080

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.