Literature DB >> 17078962

Fast gradient elution reversed-phase high-performance liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse. I. Chromatographic conditions.

Dwight R Stoll1, Changyub Paek, Peter W Carr.   

Abstract

A new approach for the high-throughput screening of biological samples to detect the presence of regulated intoxicants has been developed by modifying a conventional gradient elution high-performance liquid chromatograph (HPLC). The goal of this work was to improve the speed of gradient elution screening methods over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which is the basis for the identification of intoxicant compounds. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between consecutive gradient runs, thereby reducing the total time for each analysis. The total analysis time for each gradient elution run is only 2.80 min, including 0.30 min for column re-equilibration between analyses. Retention times of standard calibration solutes are reproducible to better than 0.002 min in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. For a set of forty-seven target compounds, the discriminating power and mean list length were found to be 0.95 and 3.26, respectively. In comparison to previous work with similar numbers of target compounds, the current approach provides an order of magnitude improvement in analysis time, and a four-fold decrease in mean list length.

Mesh:

Substances:

Year:  2006        PMID: 17078962     DOI: 10.1016/j.chroma.2006.10.017

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Fast gradient elution reversed-phase liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse. II. Data analysis.

Authors:  Sarah E G Porter; Dwight R Stoll; Changyub Paek; Sarah C Rutan; Peter W Carr
Journal:  J Chromatogr A       Date:  2006-10-27       Impact factor: 4.759

Review 2.  Fast, comprehensive two-dimensional liquid chromatography.

Authors:  Dwight R Stoll; Xiaoping Li; Xiaoli Wang; Peter W Carr; Sarah E G Porter; Sarah C Rutan
Journal:  J Chromatogr A       Date:  2007-08-30       Impact factor: 4.759

3.  Application of silica-based hyper-crosslinked sulfonate-modified reversed stationary phases for separating highly hydrophilic basic compounds.

Authors:  Hao Luo; Lianjia Ma; Changyub Paek; Peter W Carr
Journal:  J Chromatogr A       Date:  2008-06-18       Impact factor: 4.759

Review 4.  Perspectives on recent advances in the speed of high-performance liquid chromatography.

Authors:  Peter W Carr; Dwight R Stoll; Xiaoli Wang
Journal:  Anal Chem       Date:  2011-02-22       Impact factor: 6.986

5.  Instrument parameters controlling retention precision in gradient elution reversed-phase liquid.

Authors:  Ayse Beyaza; Wenzhe Fana; Peter W Carr; Adam P Schellinger
Journal:  J Chromatogr A       Date:  2014-12-05       Impact factor: 4.759

6.  Development of a carbon clad core-shell silica for high speed two-dimensional liquid chromatography.

Authors:  Changyub Paek; Yuan Huang; Marcelo R Filgueira; Alon V McCormick; Peter W Carr
Journal:  J Chromatogr A       Date:  2012-01-11       Impact factor: 4.759

7.  Improved synthesis of carbon-clad silica stationary phases.

Authors:  Imad A Haidar Ahmad; Peter W Carr
Journal:  Anal Chem       Date:  2013-11-25       Impact factor: 6.986

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.