Literature DB >> 17078472

Preanalytic indicators of laboratory performances and quality improvement of laboratory testing.

Giuseppe Lippi, Gian Cesare Guidi.   

Abstract

Laboratory diagnosis is traditionally a three-part process that develops within the preanalytic, analytic and post-analytic phases. There is consolidated evidence that lack of standardization and monitoring of preanalytic variables, including procedures for patient identification, sample collection, handling and processing has an adverse influence on the reliability of test results, consuming valuable healthcare resources and compromising the patient's outcome. The preanalytic phase enfolds the greatest potential for quality improvement, once reliable strategies are identified and applied. A comprehensive quality program should outstrip the traditional confines of clinical laboratories, encompassing reliable monitoring policies of the state of quality across the entire process. Such an approach requires the adoption of a reliable global quality monitoring system based on a core set of broad, evidence-based preanalytic performance measures. The present article synthesizes current evidence on this topic, defining a tentative approach for implementation of a preanalytic quality monitoring system in clinical laboratories.

Entities:  

Mesh:

Year:  2006        PMID: 17078472

Source DB:  PubMed          Journal:  Clin Lab        ISSN: 1433-6510            Impact factor:   1.138


  5 in total

1.  Errors in medicine and errors in laboratory medicine: what is the difference?

Authors:  Cosimo Ottomano
Journal:  Blood Transfus       Date:  2010-04       Impact factor: 3.443

2.  A new device to relieve venipuncture pain can affect haematology test results.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Marise Danielle Raulino Campelo; Katharyne Soares Adala Tajra; Flavio dos Santos Gomes; Carlos David Valentim; Sylvio José Colonna Romano; Geraldo Picheth; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2013-07-18       Impact factor: 3.443

3.  Quality impact on diagnostic blood specimen collection using a new device to relieve venipuncture pain.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Indian J Clin Biochem       Date:  2013-04-03

4.  K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Giovanni Poli; Giovanni Pietro Solero; Geraldo Picheth; Gian Cesare Guidi
Journal:  ISRN Hematol       Date:  2012-07-24

5.  Specimen rejection in laboratory medicine: Necessary for patient safety?

Authors:  Zeliha Gunnur Dikmen; Asli Pinar; Filiz Akbiyik
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.