Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification.

Jehad Al-Sukhun1, John Kelleway, Miia Helenius.   

Abstract

The purpose of this study was to mathematically validate and clinically verify a finite element model (FEM) of the human mandible and to compare the functional deformation predicted by the model with that detected clinically. Mandibular surface strain, using 11 single strain gauges, and medial convergence (MC), using a custom-fabricated linear variable differential transformer (LVDT), were recorded in a dried human jaw. The mandible was treated with two endosseous implants, placed bilaterally in the premolar area, and mounted in a rig that simulated natural function of the jaw. Measurements were made in real time using a multichannel analogue/digital converter and a personal computer for data storage and analysis. A FEM of the mandible was constructed, using commercially available finite element software, based on CT scan images of the jaw. MC was predicted as the linear change in the orientation of the two implants in the horizontal plane. Predicted and measured values of MC ranged between 60 and 109 microm. The differences between the measured and predicted strain magnitudes were expressed as absolute percentages of the measured values and ranged between 3 and 18%. The limits of agreement between the predicted and measured strain values, as suggested by Bland and Altman (Lancet 1986; 1:307-310), were small enough for the predictions from the FEM to be considered clinically acceptable. The good agreement between the predicted and measured strain values indicates the accuracy of the present FEM. Finite element analysis is a powerful technique that provides a better insight into understanding the complex phenomena of mandibular functional deformation. (c) 2006 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17078048     DOI: 10.1002/jbm.a.30894

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  5 in total

1.  Biomedical electrosurgery devices containing nanostructure for minimally invasive surgery: reduction of thermal injury and acceleration of wound healing for liver cancer.

Authors:  Wen-Tien Hsiao; Li-Hsiang Lin; Hsi-Jen Chiang; Keng-Liang Ou; Han-Yi Cheng
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

2.  Transversely isotropic and isotropic material considerations in determining the mechanical response of geometrically accurate bovine tibia bone.

Authors:  Reem A Yassine; Ramsey F Hamade
Journal:  Med Biol Eng Comput       Date:  2019-08-03       Impact factor: 2.602

3.  Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis.

Authors:  Gianni Frisardi; Sandro Barone; Armando V Razionale; Alessandro Paoli; Flavio Frisardi; Antonio Tullio; Aurea Lumbau; Giacomo Chessa
Journal:  Head Face Med       Date:  2012-05-29       Impact factor: 2.151

4.  Patient-specific finite element analysis of viscoelastic masticatory mucosa.

Authors:  Noriyuki Wakabayashi; Tetsuya Suzuki
Journal:  J Dent Biomech       Date:  2013-04-04

5.  Inclusion of periodontal ligament fibres in mandibular finite element models leads to an increase in alveolar bone strains.

Authors:  Steven W McCormack; Ulrich Witzel; Peter J Watson; Michael J Fagan; Flora Gröning
Journal:  PLoS One       Date:  2017-11-30       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.