Literature DB >> 17076857

Prospective, paired crossover comparison of multiple, single-needle plateletpheresis procedures with the Amicus and Trima Accel cell separators.

Stefano Fontana1, Livio Mordasini, Peter Keller, Behrouz Mansouri Taleghani.   

Abstract

BACKGROUND: The Baxter Amicus Version 2.51 (A) and the Gambro BCT Trima Accel Version 5.0 (T) cell separators may produce multiple platelet (PLT) concentrates within a single donation. STUDY DESIGN AND METHODS: The single-needle multiple plateletpheresis procedures of the two devices were compared in a prospective, randomized, paired crossover study in 60 donors. The 120 donations were compared for donor comfort, collection efficiency, residual white blood cell (WBC) count, and (in selected patients) corrected count increment (CCI).
RESULTS: The mean PLT yield and the resultant mean number of units per donation were significantly lower for A (6.06 x 10(11) vs. 7.48 x 10(11) and 2.57 vs. 3.19, respectively, both p < 0.001), in spite of a longer apheresis duration (89 min vs. 79 min; p < 0.001). This resulted in a higher collection rate of T (5.68 x 10(11) PLTs/hr vs. 4.10 x 10(11) PLTs/hr, p < 0.001). Residual WBC count of every unit was fewer than 5 x 10(6), but significantly fewer A-PLT donations contained more than 10(5) WBCs per unit (1 vs. 9, p = 0.008). Although the ACD-A consumption was slightly higher for A (489 mL vs. 469 mL, p = 0.04), a trend to a higher frequency of side effects was found for T (42.4% vs. 23.7%, p = 0.06). The 1-hour CCIs of 33 transfused A-PLT units were comparable with those of 43 T-PLT units (11.8 vs. 13.9, p = 0.480).
CONCLUSIONS: Both cell separators showed safe collections of up to 4 PLT units per donation with adequate CCI. T produced a higher PLT yield despite shorter apheresis duration, but with slightly higher residual WBC counts and a trend to a higher side-effect frequency.

Entities:  

Mesh:

Year:  2006        PMID: 17076857     DOI: 10.1111/j.1537-2995.2006.01009.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  7 in total

1.  Monitoring of platelet activation in platelet concentrates using transmission electron microscopy.

Authors:  Josef Neumüller; Claudia Meisslitzer-Ruppitsch; Adolf Ellinger; Margit Pavelka; Christof Jungbauer; Renate Renz; Gerda Leitner; Thomas Wagner
Journal:  Transfus Med Hemother       Date:  2013-03-14       Impact factor: 3.747

2.  Platelet Recruitment during Multiple Donor Platelet Apheresis Differs between Cell Separators.

Authors:  Stefano Fontana; Peter Keller; Behrouz Mansouri Taleghani
Journal:  Transfus Med Hemother       Date:  2011-05-11       Impact factor: 3.747

3.  Plastic-based acoustofluidic devices for high-throughput, biocompatible platelet separation.

Authors:  Yuyang Gu; Chuyi Chen; Zeyu Wang; Po-Hsun Huang; Hai Fu; Lin Wang; Mengxi Wu; Yuchao Chen; Tieyu Gao; Jianying Gong; Jean Kwun; Gowthami M Arepally; Tony Jun Huang
Journal:  Lab Chip       Date:  2019-01-29       Impact factor: 6.799

4.  Hemostatic function and transfusion efficacy of apheresis platelet concentrates treated with gamma irradiation in use for thrombocytopenic patients.

Authors:  Mei Zhu; Wei Xu; Bao-Long Wang; Hong Su
Journal:  Transfus Med Hemother       Date:  2014-05-22       Impact factor: 3.747

5.  Double Dose Plateletpheresis: A Savior to Shrinking Donor Pool and Platelet Inventory Management.

Authors:  R N Makroo; Dhaval Fadadu; Soma Agrawal; Mohit Chowdhry
Journal:  Indian J Hematol Blood Transfus       Date:  2018-01-20       Impact factor: 0.900

6.  Initial values of donor hematocrit and efficiency of plateletpheresis.

Authors:  Elvedin Landzo; Alma Sofo-Hafizovic; Vesna Cetkovic-Basic
Journal:  Acta Inform Med       Date:  2013

7.  A computerized prediction model of hazardous inflammatory platelet transfusion outcomes.

Authors:  Kim Anh Nguyen; Hind Hamzeh-Cognasse; Marc Sebban; Elisa Fromont; Patricia Chavarin; Lena Absi; Bruno Pozzetto; Fabrice Cognasse; Olivier Garraud
Journal:  PLoS One       Date:  2014-05-15       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.