Long-term follow-up of Intacs for post-LASIK corneal ectasia.

George D Kymionis1, Nikolaos S Tsiklis, Aristofanis I Pallikaris, George Kounis, Vasilios F Diakonis, Nikolaos Astyrakakis, Charalambos S Siganos.   

Abstract

OBJECTIVE: To report long-term follow-up of Intacs microthin prescription inserts for the management of post-LASIK corneal ectasia.
DESIGN: Long-term (5 years), retrospective, nonrandomized study. PARTICIPANTS: Eight eyes of 5 patients with post-LASIK corneal ectasia (3 men and 2 women) ages 31 to 54 years (mean age+/-standard deviation [SD], 41.60+/-9.24 years) who had completed 5 years of follow-up (mean follow-up +/- SD, 60.1+/-4.9 months; range, 57-68 months). INTERVENTION: Two Intacs segments, inserted in the usual fashion, were used for low myopia correction (1 each nasally and temporally), with thickness based on the residual refraction of the patients. MAIN OUTCOME MEASURES: Manifest refraction, uncorrected and best spectacle-corrected visual acuity, patient satisfaction, topography, and confocal microscopy analysis.
RESULTS: No intraoperative or late postoperative complications occurred in this series of patients. At 5 years, the SE error was statistically significantly reduced (pre-Intacs mean+/-SD, -5.47+/-2.66 diopters [D]; range, -11.50 to -3.00 D) to -2.56+/-3.44 D (range, -9.50 to 1.5 D; P = 0.01). At the end of the first postoperative year, refractive stability was obtained and remained stable during the follow-up period with no significant changes between the interval meantime (P>0.05). Pre-Intacs uncorrected visual acuity was 20/100 or worse in all eyes (range, counting fingers-20/100), whereas at the last follow-up examination, 6 (75%) of 8 eyes had uncorrected visual acuity of 20/40 or better (range, counting fingers-20/25). Two eyes (25%) maintained the pre-Intacs best spectacle-corrected visual acuity, whereas the rest of the eyes (6 eyes; 75%) experienced a gain of 1 or 2 lines. At the end of the first postoperative year, uncorrected and best-spectacle corrected visual acuity and topographic stability were obtained and were shown to have remained stable during the follow-up period with no significant changes between the interval meantime. Lamellar channel deposits were observed in confocal microscopy at or adjacent to the intrastromal ring segment.
CONCLUSIONS: Refractive stability was maintained for up to 5 years in the treatment of post-LASIK corneal ectasia after Intacs implantation. There was no evidence of progressive time-dependent corneal ectasia, late regression, or sight-threatening complications in this study.

Entities:  

Mesh:

Year:  2006        PMID: 17074560     DOI: 10.1016/j.ophtha.2006.05.043

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  16 in total

Review 1.  INTACS for keratoconus.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2006

2.  Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking.

Authors:  Kay Lam; Dan B Rootman; Alejandro Lichtinger; David S Rootman
Journal:  Digit J Ophthalmol       Date:  2013-01-06

Review 3.  INTACS for keratoconus and ectasia after LASIK.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2013

4.  Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-04-01

Review 5.  Complications of Refractive Surgery: Ectasia After Refractive Surgery.

Authors:  Meraf A Wolle; J Bradley Randleman; Maria A Woodward
Journal:  Int Ophthalmol Clin       Date:  2016

6.  Surgical technique: coupling of intrastromal corneal ring segments for ectatic corneal disorders in eye bank corneas.

Authors:  Majid Moshirfar; Maylon Hsu; Yousuf M Khalifa
Journal:  Clin Ophthalmol       Date:  2011-10-10

7.  Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique.

Authors:  Zeki Tunc; Firat Helvacioglu; Sadik Sencan
Journal:  Indian J Ophthalmol       Date:  2011 Nov-Dec       Impact factor: 1.848

8.  Intrastromal corneal ring segment implantation (keraring 355°) in patients with central keratoconus: 6-month follow-up.

Authors:  Khosrow Jadidi; Seyed Aliasghar Mosavi; Farhad Nejat; Mostafa Naderi; Leila Janani; Sara Serahati
Journal:  J Ophthalmol       Date:  2015-01-05       Impact factor: 1.909

9.  Efficacy of intacs intrastromal corneal ring segment relative to depth of insertion evaluated with anterior segment optical coherence tomography.

Authors:  Hassan Hashemi; Alireza Yazdani-Abyaneh; Amirhushang Beheshtnejad; Mahmood Jabbarvand; Ahmad Kheirkhah; Seyed Reza Ghaffary
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Jul-Sep

10.  Novel technique of fixing intracorneal rings segments after migration.

Authors:  Prateek Agarwal; Praveen Subudhi; Neha Mithal
Journal:  BMJ Case Rep       Date:  2020-01-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.