Literature DB >> 17072868

Polyurethane elastomer: a new material for the visualization of cadaveric blood vessels.

Eric P Meyer1, Gertrude M Beer, Axel Lang, Mirjana Manestar, Thomas Krucker, Sonja Meier, Daniela Mihic-Probst, Peter Groscurth.   

Abstract

A multitude of various materials are available for the visualization of cadaveric vessels, ranging from natural materials like gelatin and latex to synthetic materials like silicone rubber or acrylates. To achieve a detailed overview of the vascular architecture in microvascular studies in experimental flap surgery, the injected material should have low viscosity to assure perfusion of even the smallest vessels. In addition, the material ideally should have either no or only minimal shrinkage, and should harden within a reasonable time, but retain sufficient elasticity and resistance to withstand tearing off the delicate vessels during subsequent dissection or casting. Because none of the available injection materials adequately combines these attributes, we evaluated the polyurethane elastomer "PU4ii" in latissimus dorsi muscles as a new material for the visualization of cadaveric vessels in comparison with the frequently used silicone rubber. The dissection of vessels injected with PU4ii proved easy largely because of its exceptional hardness. Even if not visible before dissection, the completely perfused vessels were easily palpated in the surrounding fat or muscle tissue of the microsurgical latissimus dorsi model. Despite the significantly higher hardness of PU4ii over silicone rubber (98 Sh-A vs. 12 Sh-A), PU4ii proved enough elasticity (20-25 N/mm(2) E modulus) and a high tear resistance (64-68 N/mm vs. 15 N/mm) preventing breakage during dissection even within the smallest vessels. In contrast to silicone rubber (and latex or gelatin), the high corrosion resistance and form stability of PU4ii also allowed building of casts for qualitative examination by scanning electron microscopy and quantitative analysis of the vessel density using micro-computed tomography with accurate 3D representation. In this study we show that PU4ii has physical characteristics that make it a multi-purpose material that allows at the same breath an excellent gross visualization of the architecture of cadaveric blood vessels as well as a detailed evaluation of casts by modern microscopic and or radiologic tools. Thus, the new polyurethane elastomer PU4ii is in many respects superior to the widely used silicone rubber and can be strongly recommended as a visualization material for a comprehensive evaluation of cadaveric blood vessels in microsurgery.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17072868     DOI: 10.1002/ca.20403

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  10 in total

1.  Non-Trigeminal Nociceptive Innervation of the Posterior Dura: Implications to Occipital Headache.

Authors:  Rodrigo Noseda; Agustin Melo-Carrillo; Rony-Reuven Nir; Andrew M Strassman; Rami Burstein
Journal:  J Neurosci       Date:  2019-01-08       Impact factor: 6.167

2.  Setting up a microneurosurgical skull base lab: technical and operational considerations.

Authors:  Asem Salma; Andrew Chow; Mario Ammirati
Journal:  Neurosurg Rev       Date:  2011-05-26       Impact factor: 3.042

3.  Nogo-A regulates vascular network architecture in the postnatal brain.

Authors:  Thomas Wälchli; Alexandra Ulmann-Schuler; Christoph Hintermüller; Eric Meyer; Marco Stampanoni; Peter Carmeliet; Maximilian Y Emmert; Oliver Bozinov; Luca Regli; Martin E Schwab; Johannes Vogel; Simon P Hoerstrup
Journal:  J Cereb Blood Flow Metab       Date:  2016-11-13       Impact factor: 6.200

4.  A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms.

Authors:  D E Doomernik; R R Kruse; M M P J Reijnen; T L Kozicz; J G M Kooloos
Journal:  J Anat       Date:  2016-06-22       Impact factor: 2.610

5.  Quantitative analysis of hepatic macro- and microvascular alterations during cirrhogenesis in the rat.

Authors:  Geert Peeters; Charlotte Debbaut; Adrian Friebel; Pieter Cornillie; Winnok H De Vos; Kasper Favere; Ingrid Vander Elst; Tim Vandecasteele; Tim Johann; Luc Van Hoorebeke; Diethard Monbaliu; Dirk Drasdo; Stefan Hoehme; Wim Laleman; Patrick Segers
Journal:  J Anat       Date:  2017-12-04       Impact factor: 2.610

6.  A new polyvinyl alcohol hydrogel vascular model (KEZLEX) for microvascular anastomosis training.

Authors:  Tatsushi Mutoh; Tatsuya Ishikawa; Hidenori Ono; Nobuyuki Yasui
Journal:  Surg Neurol Int       Date:  2010-11-23

Review 7.  Image-based modelling of skeletal muscle oxygenation.

Authors:  B Zeller-Plumhoff; T Roose; G F Clough; P Schneider
Journal:  J R Soc Interface       Date:  2017-02       Impact factor: 4.118

8.  Role of Ryanodine Type 2 Receptors in Elementary Ca2+ Signaling in Arteries and Vascular Adaptive Responses.

Authors:  Mario Kaßmann; István András Szijártó; Concha F García-Prieto; Gang Fan; Johanna Schleifenbaum; Yoland-Marie Anistan; Christoph Tabeling; Yu Shi; Ferdinand le Noble; Martin Witzenrath; Yu Huang; Lajos Markó; Mark T Nelson; Maik Gollasch
Journal:  J Am Heart Assoc       Date:  2019-05-07       Impact factor: 5.501

9.  Common Challenges and Solutions Associated with the Preparation of Silicone-Injected Human Head and Neck Vessels for Anatomical Study.

Authors:  Musa Çırak; Kaan Yağmurlu; Sauson Soldozy; Pedro Norat; Mark E Shaffrey; Mohammad Yashar S Kalani
Journal:  Brain Sci       Date:  2020-12-31

10.  Compound ex vivo and in silico method for hemodynamic analysis of stented arteries.

Authors:  Farhad Rikhtegar; Fernando Pacheco; Christophe Wyss; Kathryn S Stok; Heng Ge; Ryan J Choo; Aldo Ferrari; Dimos Poulikakos; Ralph Müller; Vartan Kurtcuoglu
Journal:  PLoS One       Date:  2013-03-13       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.