Retrospective evaluation of temporary cemented, tooth and implant supported fixed partial dentures.

Friedhelm Heinemann1, Torsten Mundt, Reiner Biffar.   

Abstract

INTRODUCTION: The aim of this study was to examine the clinical performance of this method, and determine which temporary cement was the most appropriate.
METHODS: Dental fixtures (Tiolox implants GmbH, Germany) were implanted and crown and bridgework applied in a private practice between 1998 and 2003. Copings made of pure gold or titanium were permanently cemented onto the prepared teeth. The bridges were attached with either conventional temporary cements (Zinc oxide/ calcium hydroxide based) or acrylic/urethane cement (IMProv) both to the copings and to the implant abutments. Complications were evaluated by a retrospective review in January 2006.
RESULTS: A total of 47 patients (response: 81%) with 65 fixed partial dentures could be evaluated. Removal and re-attaching without damage of the dentures was undertaken for the following reasons: for follow-up examinations (n = 31), colour corrections (n = 15), cleaning of the dentures (n = 12), treatment of peri-implantitis (n = 2), repair following ceramic fractures (n = 5), implant failure (n = 1), tooth extractions (n = 2), root canal treatments (n = 2), occlusal corrections (n = 2), or in the case of abutment loosening (n = 4). Accidental detachments with conventional temporary cements occurred more frequently and more rapidly than with IMProv (15% versus 88.7% survival rate after four years).
CONCLUSIONS: This method for dental implant supported fixed partial dentures is successful and efficient.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17071399     DOI: 10.1016/S1010-5182(06)60019-X

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  11 in total

1.  Factors determining the retentiveness of luting agents used with metal- and ceramic-based implant components.

Authors:  Cornelia Schiessl; Lina Schaefer; Christian Winter; Jan Fuerst; Martin Rosentritt; Florian Zeman; Michael Behr
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

2.  Cemented and screw-retained implant-supported single-tooth restorations in the molar mandibular region: A retrospective comparison study after an observation period of 1 to 4 years.

Authors:  Alberto Ferreiroa; Miguel Peñarrocha-Diago; Guillermo Pradíes; María-Fernanda Sola-Ruiz; Rubén Agustín-Panadero
Journal:  J Clin Exp Dent       Date:  2015-02-01

Review 3.  The Overall Survival, Complication-Free Survival, and Related Complications of Combined Tooth-Implant Fixed Partial Dentures: A Literature Review.

Authors:  Peter Borg; James Puryer; Lisa McNally; Dominic O'Sullivan
Journal:  Dent J (Basel)       Date:  2016-05-25

4.  Modified Glass Ionomer Cement with "Remove on Demand" Properties: An In Vitro Study.

Authors:  Shaza Bishti; Taskin Tuna; Garima Agrawal; Andrij Pich; Stefan Wolfart
Journal:  Dent J (Basel)       Date:  2017-01-23

5.  Using Er:YAG laser to remove lithium disilicate crowns from zirconia implant abutments: An in vitro study.

Authors:  Janina Golob Deeb; Sompop Bencharit; Nishchal Dalal; Aous Abdulmajeed; Kinga Grzech-Leśniak
Journal:  PLoS One       Date:  2019-11-05       Impact factor: 3.240

6.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

7.  Effects of crown retrieval on implants and the surrounding bone: a finite element analysis.

Authors:  Serhat Emre Ozkir; Server Mutluay Unal; Emel Yurekli; Sedat Güven
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

8.  Influence of Luting Materials on the Retention of Cemented Implant-Supported Crowns: An In Vitro Study.

Authors:  Ella A Naumova; Felix Roth; Berit Geis; Christine Baulig; Wolfgang H Arnold; Andree Piwowarczyk
Journal:  Materials (Basel)       Date:  2018-09-28       Impact factor: 3.623

9.  Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces.

Authors:  Fusun Ozer; Elif Pak-Tunc; Nesrin Esen Dagli; Deepika Ramachandran; Deniz Sen; Markus Bernhard Blatz
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

10.  Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot.

Authors:  Kyu-Hyung Choi; KeunBaDa Son; Du-Hyeong Lee; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.