Literature DB >> 17070631

Partially cemented AncaDualFit hip stems do not fail in simulated active patients.

Luca Cristofolini1, Paolo Erani, Amelia Saponara Teutonico, Francesco Traina, Marco Viceconti, Aldo Toni.   

Abstract

BACKGROUND: Partially cemented hip stems have been introduced to offer the advantages of cemented stems on the short-term, and of cementless ones on the long-term. One such device, the AncaDualFit, has been thoroughly validated pre-clinically under average loading conditions. Concerns recently arose concerning the long-term endurance of such implants in active patients. In fact, it was suspected that cyclic loads applied by demanding patients could lead to fixation failure.
METHODS: The long-term performance of the AncaDualFit partially cemented stem was studied in vitro, using a validated protocol that simulated the loads of 24 years of an active patient. Inducible and permanent micromotions were measured in five specimens and compared against two well-established cemented stems, and a cementless stem (the original design from which was derived). Cement damage (fatigue cracks) due to cyclic loading was quantified and compared against the cemented stems.
FINDINGS: Inducible and permanent micromotions of the AncaDualFit partially cemented stem were slightly larger that the cemented stems, but much smaller than the cementless one. The migration, however, indicated a clear trend towards stabilization. Cement damage was minimal, even if compared to the most successful cemented stems. Short cracks were observed only near the cement inlet, but did not propagate in the two cement pockets.
INTERPRETATION: The partially cemented AncaDualFit stem can safely withstand very severe loading without significant damage, thanks to the design of the two anterior and posterior cement pockets. Results are reassuring also in comparison with other successful designs. Thus, it can be safely used, even in active patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17070631     DOI: 10.1016/j.clinbiomech.2006.09.003

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  2 in total

1.  Interface micromotion of uncemented femoral components from postmortem retrieved total hip replacements.

Authors:  Kenneth A Mann; Mark A Miller; Peter A Costa; Amos Race; Timothy H Izant
Journal:  J Arthroplasty       Date:  2011-07-01       Impact factor: 4.757

2.  Outcome of hybrid stem fixation in osteoporotic female patients. A minimum five-year follow-up study.

Authors:  Francesco Traina; Enrico Tassinari; Federico Pilla; Marcello De Fine; Federico Biondi; Luca Cristofolini; Aldo Toni
Journal:  Int Orthop       Date:  2008-08-20       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.