Performance of frequency-doubling technology perimetry in a population-based prevalence survey of glaucoma: the Tajimi study.

Aiko Iwase1, Atsuo Tomidokoro, Makoto Araie, Shiroaki Shirato, Hiroyuki Shimizu, Yoshiaki Kitazawa.   

Abstract

OBJECTIVE: To evaluate the performance of frequency-doubling technology (FDT) perimetry in a population-based glaucoma prevalence survey.
DESIGN: Population-based cross-sectional study. PARTICIPANTS: Participants older than 40 years randomly selected from the population of Tajimi City.
METHODS: Each participant underwent screening ophthalmic examinations including a visual field test using FDT with the C-20-1 screening protocol. A diagnosis of glaucoma was determined by glaucoma specialists with another detailed visual field test using Humphrey Field Analyzer (HFA; Humphrey Instruments, San Leandro, CA) with the 30-2 Swedish interactive threshold algorithm standard protocol and stereoscopic disc photographs. MAIN OUTCOME MEASURES: The ratios of reliable FDT results and the sensitivity and specificity for detecting glaucoma in a general population.
RESULTS: Of 5784 eyes of 2892 participants (age range, 40-92 years; refractive error, -23 to 11 diopters) in whom FDT was performed in both eyes, reliable results (< or =33% fixation loss and < or =33% false-positive errors) were obtained in 5707 eyes (98.7%), including 2871 right eyes (99.3%) and 2836 left eyes (98.1%) with a significant bilateral difference (P<0.001, chi-square test). The rate of reliable FDT results did not differ between men and women (P = 0.81) but decreased with age. In 5582 eyes with reliable FDT results, FDT showed 1 or more abnormal points in the visual field in 502 eyes (9.0%), including 388 (7.3%) of 5295 normal eyes, 19 (16.4%) of 116 eyes of glaucoma suspects, and 95 (55.6%) of 171 eyes with definite glaucoma. The sensitivity and specificity values for detecting definite glaucoma were 55.6% and 92.7%, respectively. The positive and negative predictive values were 18.9% and 98.5%, respectively. In further analyses stratified with the mean deviation (MD) of the HFA, the sensitivities were 32.1%, 48.4%, 73.7%, and 96.6% for detecting definite glaucoma with an MD of more than -2 dB, an MD of -2 dB or less and more than -5 dB, an MD of -5 dB or less and more than -8 dB, and an MD of -8 dB or less, respectively.
CONCLUSIONS: In a population-based glaucoma screening study, FDT perimetry with the C-20-1 screening protocol was reliably performed in more than 98% of participants. The sensitivity for detecting glaucomatous visual field damages, especially early damage, was not sufficiently high, whereas the specificity was high.

Entities:  

Mesh:

Year:  2006        PMID: 17070580     DOI: 10.1016/j.ophtha.2006.06.041

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  17 in total

1.  Influence of axial length on ganglion cell complex (GCC) thickness and on GCC thickness to retinal thickness ratios in young adults.

Authors:  Asuka Takeyama; Yoshiyuki Kita; Ritsuko Kita; Goji Tomita
Journal:  Jpn J Ophthalmol       Date:  2013-11-19       Impact factor: 2.447

2.  Population and high-risk group screening for glaucoma: the Los Angeles Latino Eye Study.

Authors:  Brian A Francis; Rohit Varma; Cheryl Vigen; Mei-Ying Lai; Jonathan Winarko; Betsy Nguyen; Stanley Azen
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-08-05       Impact factor: 4.799

3.  Predictive value of screening tests for visually significant eye disease.

Authors:  Laura J Kopplin; Steven L Mansberger
Journal:  Am J Ophthalmol       Date:  2015-06-04       Impact factor: 5.258

4.  Gaps in Glaucoma care: A systematic review of monoscopic disc photos to screen for glaucoma.

Authors:  Paula Anne Newman-Casey; Angela J Verkade; Gale Oren; Alan L Robin
Journal:  Expert Rev Ophthalmol       Date:  2014-12

5.  Combining Optical Coherence Tomography and Fundus Photography to Improve Glaucoma Screening.

Authors:  Tomoyuki Watanabe; Yoshimune Hiratsuka; Yoshiyuki Kita; Hiroshi Tamura; Ryo Kawasaki; Tetsuji Yokoyama; Motoko Kawashima; Tadashi Nakano; Masakazu Yamada
Journal:  Diagnostics (Basel)       Date:  2022-04-27

6.  Risk factors for glaucoma are reflected in abnormal responses to frequency-doubling technology screening in both normal and glaucoma eyes.

Authors:  Aiko Iwase; Tae Tsutsumi; Makoto Fujii; Shoichi Sawaguchi; Makoto Araie
Journal:  Sci Rep       Date:  2022-07-09       Impact factor: 4.996

Review 7.  Diagnostic tools for glaucoma detection and management.

Authors:  Pooja Sharma; Pamela A Sample; Linda M Zangwill; Joel S Schuman
Journal:  Surv Ophthalmol       Date:  2008-11       Impact factor: 6.048

8.  Prevalence and characteristics of glaucoma among Korean adults.

Authors:  Ji Hyun Kim; Sung Yong Kang; Na Rae Kim; Eun Suk Lee; Samin Hong; Gong Je Seong; Young Jae Hong; Chan Yun Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

9.  Five year incidence of visual field loss in adult Chinese. The Beijing Eye Study.

Authors:  Ya Xing Wang; Liang Xu; Xiu Ying Sun; Yang Zou; Hai Tao Zhang; Jost B Jonas
Journal:  PLoS One       Date:  2012-05-18       Impact factor: 3.240

10.  Developing the specifications of an open angle glaucoma screening intervention in the United Kingdom: a Delphi approach.

Authors:  Susan E Campbell; Augusto Azuara-Blanco; Marion K Campbell; Jillian J Francis; Alexandra C Greene; Craig R Ramsay; Jennifer M Burr
Journal:  BMC Health Serv Res       Date:  2012-12-05       Impact factor: 2.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.