Literature DB >> 17069423

[Stability of busulfan injection solution (Busilvex, Busulfex) in B/Braun Injekt syringes].

A Karstens1, I Krämer.   

Abstract

Stability of busulfan injection solution (Busilvex, Busulfex) in B/Braun Injekt syringes Stability of busulfan injection was determined by a modified stability-indicating HPLC method with UV detection. Diethyldithiocarbamate was used as derivatization agent. The stability tests revealed that busulfan injection (Busilvex, Busulfex) stored in B/Braun Injekt syringes at 18-20 degrees C without light protection or refrigerated are stable for up to 28 days. Unused busulfan injection (Busilvex, Busulfex) is not necessarily to be discarded, but can be stored for a prolonged period of time in a rubber free syringe, preferably under refrigeration.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17069423

Source DB:  PubMed          Journal:  Pharmazie        ISSN: 0031-7144            Impact factor:   1.267


  1 in total

1.  Physico-chemical stability of busulfan in injectable solutions in various administration packages.

Authors:  Mélanie Houot; Vianney Poinsignon; Lionel Mercier; Cyril Valade; Romain Desmaris; François Lemare; Angelo Paci