Literature DB >> 17069166

Influence of interimplant distance on papilla formation and bone resorption: a clinical-radiographic study in dogs.

Rafael R de Oliveira1, Arthur B Novaes, Vula Papalexiou, Valdir A Muglia, Mário Taba.   

Abstract

Implant esthetics has been the focus of attention for the past decade, and one vital issue is the effect of interimplant distance on interimplant papilla formation and crestal bone loss. The aim of this study was to evaluate the effect of 1, 2, and 3 mm of interimplant distance on papilla formation and crestal resorption in submerged and nonsubmerged Ankylos implants after prosthetic restoration. Bilateral mandibular premolars of 7 dogs were extracted, and after 12 weeks each dog received 8 implants. Implants were placed so that 3 interimplant distances were created at 1 mm (group 1), 2 mm (group 2), and 3 mm (group 3). The sides and the position of the groups were randomly selected. Twelve weeks after placement, the implants received metallic prostheses that allowed 5 mm of space between the prosthetic contact point (CP) and the crestal bone (CB). After 8 weeks, the distance between the CP and the papilla (CP-P) and the gingival height at the distal proximal aspect of the prosthesis (CP-DE) was clinically measured. Radiographic images were obtained to measure the distance of the CP to the CB within the interimplant surfaces (CP-IP) and adjacent to the edentulous surfaces (CP-ED). The clinical measurement of CP-P for submerged and nonsubmerged implants was 3.57+/-1.17 mm and 3.10+/-0.82 mm for group 1, 3.57+/-0.78 mm and 3.16+/- 0.87 mm for group 2, and 3.35+/- 0.55 mm and 3.07+/-0.93 mm for group 3. The CP-DE was 3.25+/-0.77 mm for submerged and 2.78+/- 0.64 mm for nonsubmerged implants. The CP-IP for the submerged and nonsubmerged implants was 6.91+/-0.95 mm and 7.68+/-2.73 mm for group 1, 7.46+/-1.43 mm and 5.87+/-1.71 mm for group 2, and 7.72+/-0.81 mm and 7.59+/-1.33 mm for group 3. The CP-ED was 6.77+/-1.33 mm for submerged implants and 6.03+/-1.58 mm for nonsubmerged implants. There were no statistical significant differences for any of the measured parameters. We conclude that when the distance from the CP to the CB was 5 mm, interimplant distances of 1 to 3 mm did not affect papilla formation or crestal resorption of submerged or nonsubmerged implants in the dog model.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17069166     DOI: 10.1563/793.1

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Case presentation of two patients using diagonal platform-switched double implants for maxillary single-first-molar replacement as the alternative of a single-tooth implant.

Authors:  Yasunori Hotta; Koji Ito; Shinichi Komatsu; Takashi Saito
Journal:  Int J Implant Dent       Date:  2015-11-12

Review 2.  Morse taper dental implants and platform switching: The new paradigm in oral implantology.

Authors:  José Paulo Macedo; Jorge Pereira; Brendan R Vahey; Bruno Henriques; Cesar A M Benfatti; Ricardo S Magini; José López-López; Júlio C M Souza
Journal:  Eur J Dent       Date:  2016 Jan-Mar

3.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.