Literature DB >> 17068375

Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements and Monte Carlo simulations.

C F Behrens1.   

Abstract

It has been shown in several studies that the build-up in photon beams behind air cavities (such as in the head and neck) increases with energy. In this study this effect is investigated over a broad range of energies that have been used for treating head and neck tumours. The study addresses the question of whether an energy lower than 6 MV is desirable and is based on measurements and Monte Carlo (MC) simulations. In a PMMA phantom containing an air cavity (3 x 16 x 3 cm3 at 3 cm depth) an ionization chamber (Capintec PS-033) was used to measure the dose build-up behind the cavity for 4, 6 and 8 MV beam qualities for different field sizes (from 3 x 6 cm2 to 8 x 8 cm2). MC simulations were made using the EGSnrc code for the same geometry and energies as well as for Co-60. Measurements and MC simulations agree well when the fixed-separation plane-parallel chamber measurements have been corrected for the expected over-response in the build-up region. This work demonstrates that the build-up effect of 6 MV is 'closer' to the build-up effect of 8 MV than to that of 4 MV. This suggests that if the build-up effect is of concern when the target volume is in the vicinity of air cavities, 4 MV should be preferred over both 6 MV and 8 MV. This work also shows that the build-up effect for Co-60 is significantly smaller than that of 4 MV. Moreover, the build-up effect increases as the field size decreases. With the increasing use of IMRT (and radiosurgery), small fields are used more frequently making these issues even more relevant. This should be taken into consideration when choosing the accelerator energies for a radiotherapy department.

Entities:  

Mesh:

Year:  2006        PMID: 17068375     DOI: 10.1088/0031-9155/51/22/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Accuracy Evaluation of Collapsed Cone Convolution Superposition Algorithms for the Nasopharynx Interface in the Early Stage of Nasopharyngeal Carcinoma.

Authors:  Yuan-Chun Lai; Li-Chung Hung; Chien-Chung Jeng; Chen-Ju Feng; Tung-Hao Chang; Shih-Ming Hsu
Journal:  Biomed Res Int       Date:  2022-05-28       Impact factor: 3.246

2.  Dosimetry of interface region near closed air cavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations.

Authors:  Chandra P Joshi; Johnson Darko; P B Vidyasagar; L John Schreiner
Journal:  J Med Phys       Date:  2010-04

3.  Investigating the Effect of Air Cavities of Sinuses on the Radiotherapy Dose Distribution Using Monte Carlo Method.

Authors:  F Seif; M R Bayatiani; S Hamidi; M Kargaran
Journal:  J Biomed Phys Eng       Date:  2019-02-01

4.  3D-printed bolus ensures the precise postmastectomy chest wall radiation therapy for breast cancer.

Authors:  Xiran Wang; Jianling Zhao; Zhongzheng Xiang; Xuetao Wang; Yuanyuan Zeng; Ting Luo; Xi Yan; Zhuang Zhang; Feng Wang; Lei Liu
Journal:  Front Oncol       Date:  2022-09-02       Impact factor: 5.738

5.  Dosimetric Evaluation of Commercially Available Flat vs. Self-Produced 3D-Conformal Silicone Boluses for the Head and Neck Region.

Authors:  Stephan Pollmann; André Toussaint; Michael Flentje; Sonja Wegener; Victor Lewitzki
Journal:  Front Oncol       Date:  2022-08-10       Impact factor: 5.738

6.  Workload implications for clinic workflow with implementation of three-dimensional printed customized bolus for radiation therapy: A pilot study.

Authors:  Eric Ehler; David Sterling; Kathryn Dusenbery; Jessica Lawrence
Journal:  PLoS One       Date:  2018-10-01       Impact factor: 3.240

7.  Evaluation of the quality of fit of flexible bolus material created using 3D printing technology.

Authors:  Ciaran Malone; Elaine Gill; Tanith Lott; Catherine Rogerson; Sinead Keogh; Majed Mousli; Denise Carroll; Caitriona Kelly; John Gaffney; Brendan McClean
Journal:  J Appl Clin Med Phys       Date:  2022-01-20       Impact factor: 2.102

8.  Energy Modulated Photon Radiotherapy: A Monte Carlo Feasibility Study.

Authors:  Ying Zhang; Yuanming Feng; Xin Ming; Jun Deng
Journal:  Biomed Res Int       Date:  2016-02-09       Impact factor: 3.246

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.