Literature DB >> 17067621

Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice.

Maria Sejersten1, Galen S Wagner, Olle Pahlm, James W Warren, Charles L Feldman, B Milan Horácek.   

Abstract

ST-segment measurements in the standard 12-lead electrocardiogram (ECG) of patients with acute coronary syndromes are crucial for these patients' management. Our objective was to determine whether the 12-lead ECG derived from the 3-lead EASI system can attain a level of diagnostic performance similar to that of the Mason-Likar (ML) 12-lead ECG acquired in clinical practice (CP) by paramedics and emergency department technicians. Using 120-lead body surface potential maps recorded before and during balloon inflation angioplasty from 88 patients (divided into "responders" and "nonresponders"), and electrode placement data from 60 applications of precordial leads in CP, we generated for the "nonischemic" and "ischemic" states of each patient the following lead sets: the ML 12-lead ECG, the EASI-derived 12-lead ECG, and 60 sets of 12-lead CP ECGs. We extracted ST deviations at J + 60 milliseconds, summed them for all 12 leads of each lead set to obtain SigmaST, and, by using the bootstrap method, determined the mean sensitivity and specificity for recognizing the "ischemic" state at various thresholds of SigmaST. Results were displayed as receiver operating characteristics, and the area under these curves (AUC) +/- SE was used as the measure of diagnostic performance. AUC +/- SE for all patients were ML ECG, 0.66 +/- 0.03; EASI ECG, 0.64 +/- 0.03; and CP ECG, 0.67 +/- 0.03. Corresponding results for responders only were 0.81 +/- 0.04 for ML ECG, 0.78 +/- 0.04 for EASI ECG, and 0.81 +/- 0.04 for CP ECG. The differences between the AUCs for the different lead sets were not significant (P > .05). Thus, the EASI-derived 12-lead ECG is as good for detecting acute ischemia as is the 12-lead ECG acquired in CP.

Entities:  

Mesh:

Year:  2006        PMID: 17067621     DOI: 10.1016/j.jelectrocard.2006.08.099

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  1 in total

1.  A 66-Year-Old Woman with Intermittent Chest Pain and Dyspnea Who Underwent Continued ST-Segment Monitoring to Identify Occult ST-Segment Elevation that Expedited Coronary Angiography and Revascularization.

Authors:  Philip Caap; Jens Christian Herman Jensen; Morten Schmidt
Journal:  Am J Case Rep       Date:  2021-03-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.