Literature DB >> 17066941

Comparison of a rapid ATP bioluminescence assay and standard plate count methods for assessing microbial contamination of consumers' refrigerators.

Fur-Chi Chen1, Sandria L Godwin.   

Abstract

The feasibility of using an ATP bioluminescence assay for assessing microbial contamination of home refrigerators was evaluated and compared with the standard culture methods. Samples of refrigerator surfaces were collected from 123 households by swabbing an area of 100 cm2 on three locations in the refrigerator with premoisturized sterile swabs. Microbial contaminations were determined by aerobic plate count (APC; incubated at 35 degrees C for 48 h) and psychrotrophic plate count (PPC; incubated at 7 degrees C for 10 days) on plate count agar. The results were compared to the readings from the microbial ATP (mATP) bioluminescence assay. The correlation coefficient (r) between mATP and PPC (r = 0.851) was slightly higher than that between mATP and APC (r = 0.823). Our results indicated a potential discrepancy in the population of mesophilic and psychrotrophic bacteria in the refrigerator samples. Nevertheless, mATP appeared to be a reliable indication of the average of APC and PPC (r = 0.895). The mATP bioluminescence assay would provide a rapid and convenient test for researchers in field studies to assess microbial contamination in refrigerators.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17066941     DOI: 10.4315/0362-028x-69.10.2534

Source DB:  PubMed          Journal:  J Food Prot        ISSN: 0362-028X            Impact factor:   2.077


  7 in total

1.  Optical biosensors for food quality and safety assurance-a review.

Authors:  K Narsaiah; Shyam Narayan Jha; Rishi Bhardwaj; Rajiv Sharma; Ramesh Kumar
Journal:  J Food Sci Technol       Date:  2011-07-06       Impact factor: 2.701

2.  Biosynthesis of staphylococcal enterotoxin A by genetic engineering technology and determination of staphylococcal enterotoxin A in water by HPLC-ESI-TOF.

Authors:  Hong-Na Li; Fei Yuan; Yun-Jing Luo; Jian-Feng Wang; Chuan-Bin Zhang; Wei-E Zhou; Zhi-Qin Ren; Wen-Jie Wu; Feng Zhang
Journal:  Environ Sci Pollut Res Int       Date:  2017-07-04       Impact factor: 4.223

3.  Quantitative evaluation of bacteria adherent and in biofilm on single-wall carbon nanotube-coated surfaces.

Authors:  Fabrizio Pantanella; Francesca Berlutti; Daniele Passeri; Daniela Sordi; Alessandra Frioni; Tiziana Natalizi; Maria Letizia Terranova; Marco Rossi; Piera Valenti
Journal:  Interdiscip Perspect Infect Dis       Date:  2011-10-05

4.  BioTimer assay as complementary method to vortex-sonication-vortex technique for the microbiological diagnosis of implant associated infections.

Authors:  Luigi Rosa; Maria Stefania Lepanto; Antimo Cutone; Francesca Berlutti; Massimiliano De Angelis; Vincenzo Vullo; Claudio Maria Mastroianni; Piera Valenti; Alessandra Oliva
Journal:  Sci Rep       Date:  2019-05-17       Impact factor: 4.379

5.  Evaluation of Rodent Cage Processing Using Reduced Water Temperatures.

Authors:  Mary M Walker; Dianne M Harrison; Toi A Collins; Valerie K Bergdall
Journal:  J Am Assoc Lab Anim Sci       Date:  2021-06-28       Impact factor: 1.706

6.  How reliable are ATP bioluminescence meters in assessing decontamination of environmental surfaces in healthcare settings?

Authors:  Navid Omidbakhsh; Faraz Ahmadpour; Nicole Kenny
Journal:  PLoS One       Date:  2014-06-18       Impact factor: 3.240

7.  The Influence of Surface Topography and Wettability on Escherichia coli Removal from Polymeric Materials in the Presence of a Blood Conditioning Film.

Authors:  I Devine Akhidime; Anthony J Slate; Anca Hulme; Kathryn A Whitehead
Journal:  Int J Environ Res Public Health       Date:  2020-10-09       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.