Anxiety and depression in patients with life-threatening ventricular arrhythmias: impact of the implantable cardioverter-defibrillator.

R Keren1, D Aarons, E P Veltri.   

Abstract

In order to assess the psychological responses to the automatic implantable cardioverter-defibrillator (AICD), 18 patients with a history of life-threatening ventricular arrhythmias were requested to complete the Spielberger State-Trait Anxiety Inventory and the Beck Depression Inventory. The patients were divided into three groups of six and matched for age, sex, underlying cardiac disease, ejection fraction, and NYHA Functional Classification. Group I had experienced conscious discharges from the AICD, group II had the AICD but without discharges, and group III without the AICD were treated with antiarrhythmic medications alone based on electrophysiological guided testing. Patients with the AICD were also requested to complete a questionnaire directed specifically at their experiences with the AICD. All of the 18 patients completed the study responses and results were analyzed by blinded review. There were no significant differences in anxiety and depression scores in the three groups studied, nor any significant differences in responses to the questionnaire in group I versus group II. One patient in group I reported experiencing adverse psychological responses to the AICD. Although there appears to be no significant differences in psychological responses as a result of the AICD implantation in patients with life-threatening ventricular arrhythmias, further study with larger patient groups is needed to identify and support patients who may develop adverse responses to the AICD.

Entities:  

Mesh:

Year:  1991        PMID: 1706503     DOI: 10.1111/j.1540-8159.1991.tb05088.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

1.  The impact of defibrillator discharges on psychological functioning of implantable cardioverter defibrillator recipients.

Authors:  V Konstam; C Colburn; L Butts; N A Mark Estes
Journal:  J Clin Psychol Med Settings       Date:  1996-03

2.  Implications for present and future applications of the implantable cardioverter-defibrillator resulting from the use of a simple model of cost efficacy.

Authors:  M H Anderson; A J Camm
Journal:  Br Heart J       Date:  1993-01

3.  Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators.

Authors:  J P Bourke; D Turkington; G Thomas; J M McComb; M Tynan
Journal:  Heart       Date:  1997-12       Impact factor: 5.994

4.  Cognitive and behavioral treatments for anxiety and depression in a patient with an implantable cardioverter defibrillator (ICD): a case report and clinical discussion.

Authors:  Adam T Hirsh; Samuel F Sears; Jamie B Conti
Journal:  J Clin Psychol Med Settings       Date:  2009-04-30

5.  Panic disorders and agoraphobia: side effects of treatment with an implantable cardioverter/defibrillator.

Authors:  Frank Godemann; Christian Butter; Felix Lampe; Michael Linden; Michael Schlegl; Hans-Peter Schultheiss; Steffen Behrens
Journal:  Clin Cardiol       Date:  2004-06       Impact factor: 2.882

Review 6.  Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods.

Authors:  Gian Mauro Manzoni; Gianluca Castelnuovo; Angelo Compare; Francesco Pagnini; Vidal Essebag; Riccardo Proietti
Journal:  Front Psychol       Date:  2015-02-04