Literature DB >> 17063765

Contact angle analysis on polymethylmethacrylate and commercial wax by using an environmental scanning electron microscope.

Marco Brugnara1, Claudio Della Volpe, Stefano Siboni, Dario Zeni.   

Abstract

The environmental scanning electron microscope (ESEM) represents one of the most exciting breakthroughs in electron microscopy since the invention of the electron microscope. Its ability to observe uncoated and hydrated samples enhances the possibility for investigating the wettability of surfaces at a microscopic level; by varying the relative vapour pressure or the temperature inside the chamber, it is possible to condense water drops on a micron scale. A large problem in measuring contact angles by ESEM is that the observation angle is not parallel or perpendicular to the surface; thus, the study of the droplets profile using the common algorithms such as spherical approximation or axisymmetric drop shape analysis (ADSA) is not possible, because only a spherical cap shape is commonly observed. In this paper we provide a useful mathematical model to calculate the real contact angle from the initial images. Initially, some simulated spherical caps with different contact and observation angles were created by an appropriate graphic package in order to test the mathematical model. Some real drops obtained by ESEM on wax and polymethylmethacrylate (PMMA) were then studied and the results compared with contact angles measured by common methods on the same materials.

Entities:  

Year:  2006        PMID: 17063765     DOI: 10.1002/sca.4950280504

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  4 in total

1.  Self-assembled monolayers of phosphonates promote primary chondrocyte adhesion to silicon dioxide and polyvinyl alcohol materials.

Authors:  Patrick E Donnelly; Laurianne Imbert; Kirsty L Culley; Russell F Warren; Tony Chen; Suzanne A Maher
Journal:  J Biomater Sci Polym Ed       Date:  2019-01-12       Impact factor: 3.517

2.  Sub-micrometer dropwise condensation under superheated and rarefied vapor condition.

Authors:  Sushant Anand; Sang Young Son
Journal:  Langmuir       Date:  2010-10-13       Impact factor: 3.882

3.  Bone Cements Used for Hip Prosthesis Fixation: The Influence of the Handling Procedures on Functional Properties Observed during In Vitro Study.

Authors:  Alina Robu; Robert Ciocoiu; Aurora Antoniac; Iulian Antoniac; Anca Daniela Raiciu; Horatiu Dura; Norin Forna; Mihai Bogdan Cristea; Ioana Dana Carstoc
Journal:  Materials (Basel)       Date:  2022-04-19       Impact factor: 3.748

4.  Early Immune Response in Foreign Body Reaction Is Implant/Material Specific.

Authors:  Nicolas Söhling; Muriel Ondreka; Kerstin Kontradowitz; Tobias Reichel; Ingo Marzi; Dirk Henrich
Journal:  Materials (Basel)       Date:  2022-03-16       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.