Literature DB >> 1706231

Diagnostic and prognostic utility of phospholipase A activity in patients with acute pancreatitis: comparison with amylase and lipase.

S C Kazmierczak1, F Van Lente, E D Hodges.   

Abstract

We compared the diagnostic and prognostic utility of phospholipase A (PLA; EC 3.1.1.4) for acute pancreatitis with that of amylase and lipase by analysis of sera from 151 consecutive patients presenting with abdominal pain in whom assays of serum amylase and (or) lipase had been ordered. We determined the diagnostic accuracy for both the initial and the peak enzyme activities. Maximal diagnostic accuracy obtained for the initial activities of amylase, lipase, and PLA was 0.83, 0.83, and 0.76 at cutoff values of 650, 650, and 41 U/L, respectively. Use of peak enzyme activities showed maximal diagnostic accuracy of 0.85, 0.86, and 0.73 at cutoff values of 650, 1050, and 42 U/L, respectively. Receiver-operator characteristic curve analysis revealed the diagnostic performance of amylase and lipase to be similar, whereas that of PLA was almost random and not incremental. As with amylase and lipase, PLA activities in sera showed no relation to patients' survival; three patients who died after an attack of acute pancreatitis failed to demonstrate the dramatic increases in PLA activity previously described. We conclude that assessing the severity of acute pancreatitis by using enzyme activities still remains problematical. Measurements of amylase or lipase activities provide similar diagnostic discrimination when appropriate cutoff values are used and remain the methods of choice for diagnosis of acute pancreatitis.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1706231

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  3 in total

Review 1.  Serum amylase and lipase and urinary trypsinogen and amylase for diagnosis of acute pancreatitis.

Authors:  Gianluca Rompianesi; Angus Hann; Oluyemi Komolafe; Stephen P Pereira; Brian R Davidson; Kurinchi Selvan Gurusamy
Journal:  Cochrane Database Syst Rev       Date:  2017-04-21

2.  A novel cerium(iii)-isatin Schiff base complex: spectrofluorometric and DFT studies and application as a kidney biomarker for ultrasensitive detection of human creatinine.

Authors:  Sheta M Sheta; Magda A Akl; Heba E Saad; El-Sayed R H El-Gharkawy
Journal:  RSC Adv       Date:  2020-02-05       Impact factor: 4.036

3.  Measurement of creatinine in human plasma using a functional porous polymer structure sensing motif.

Authors:  Sitansu Sekhar Nanda; Seong Soo A An; Dong Kee Yi
Journal:  Int J Nanomedicine       Date:  2015-08-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.