Literature DB >> 17061407

Two-years surveillance of fungal contamination in three hospital departments in Campania region.

L Brunetti1, E Santoro, P Cavallo, G Boccia, O Motta, M Capunzo.   

Abstract

A two-years (2003-2005) fungal environmental surveillance was carried out in three departments of a hospital in Campania region (Surgery, Intensive Care Unit, Obstetrics and Gynaecology). Four operating theatres rooms and their relative areas of service and support, 4 patient rooms of intensive care unit, 1 delivery room, 1 labour room and 1 nursery of Obstetrics and Gynaecology were checked. A total of 12,120 surfaces and 2,904 air samples were collected in 24 monthly determinations. A seasonal variation in the fungal development was observed, in particular the lowest level of air and surface fungi contamination was found in winter and autumn whereas it was higher in spring and summer. In this study 30 fungal species were identified and, among these, the most frequent specie isolated was the Aspergillus spp. The results show an air contamination, expressed in percentage of positive determinations for Aspergillus spp, and the other fungi in the following percentages: Obstetrics and Gynaecology (25% and 33,3%); Intensive Care Unit (17% and 25%); Surgery (12.5% and 21%). For surfaces contamination it was found: Obstetrics and Gynaecology (67% and 75%); Intensive Care Unit (63% and 71%); Surgery (58.3% and 67%). This study shows that in the departments observed environmental fungi contamination is always present and therefore it would be necessary to apply environmental surveillance procedure and monitor the effectiveness.

Entities:  

Mesh:

Year:  2006        PMID: 17061407

Source DB:  PubMed          Journal:  J Prev Med Hyg        ISSN: 1121-2233


  4 in total

1.  A study of air microbe levels in different areas of a hospital.

Authors:  Ginés Ortiz; Genoveva Yagüe; Manuel Segovia; Vicente Catalán
Journal:  Curr Microbiol       Date:  2009-03-28       Impact factor: 2.188

2.  Analyzing the risk factors influencing surgical site infections: the site of environmental factors.

Authors:  Jose L Alfonso-Sanchez; Isabel M Martinez; Jose M Martín-Moreno; Ricardo S González; Francisco Botía
Journal:  Can J Surg       Date:  2017-06       Impact factor: 2.089

3.  An alternative approach for the decontamination of hospital settings.

Authors:  Giuseppina Moccia; Oriana Motta; Concetta Pironti; Antonio Proto; Mario Capunzo; Francesco De Caro
Journal:  J Infect Public Health       Date:  2020-10-21       Impact factor: 3.718

4.  The influence of microclimate conditions on ozone disinfection efficacy in working places.

Authors:  Concetta Pironti; Giuseppina Moccia; Oriana Motta; Giovanni Boccia; Gianluigi Franci; Emanuela Santoro; Mario Capunzo; Francesco De Caro
Journal:  Environ Sci Pollut Res Int       Date:  2021-07-27       Impact factor: 4.223