Literature DB >> 17058310

Headspace single-drop microextraction with in-drop derivatization and capillary electrophoretic determination for free cyanide analysis.

Svetlana Jermak1, Birute Pranaityte, Audrius Padarauskas.   

Abstract

A new method involving headspace single-drop microextraction (SDME) with in-drop derivatization and CE is developed for the preconcentration and determination of free cyanide. An aqueous microdrop (5 microL) containing Ni(II)-NH(3) (as derivatization agent), sodium carbonate and ammonium pyromellitate (as internal standard) was used as the acceptor phase. The extracted cyanide forms a stable Ni(CN)(4) (2-) complex which is then determined by CE. Common experimental parameters (sample and acceptor phase pH, extraction temperature, extraction time and sample ionic strength) affecting the extraction efficiency were investigated. Using headspace SDME, free cyanide can be effectively extracted from the neutral solutions, i.e. without the acidification of the sample which often is prone to errors due to incomplete liberation and artefactual cyanide production. Proposed SDME-CE method provided about 58-fold enrichment in 20 min. The calibration curve was linear for concentrations of CN(-) in the range from 0.25 to 20 micromol/L (R(2) = 0.997). The LOD (S/N = 3) was estimated to be 0.08 micromol/L of CN(-). Such a detection sensitivity is high enough for free cyanide determination in common environmental and physiological samples. Finally, headspace SDME was applied to determine free cyanide in human saliva and urine samples with spiked recoveries in the range of 91.7-105.6%. The main advantage of this method is that sample clean-up, preconcentration and derivatization procedures can be completed in a single step. In addition, the proposed technique does not require any sample pretreatment and thus is much less susceptible to interferences compared to existing methods.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17058310     DOI: 10.1002/elps.200600295

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  6 in total

Review 1.  Recent developments in cyanide detection: a review.

Authors:  Jian Ma; Purnendu K Dasgupta
Journal:  Anal Chim Acta       Date:  2010-06-04       Impact factor: 6.558

2.  Alternate injections coupled with flow-gated capillary electrophoresis for rapid and accurate quantitative analysis of urine samples.

Authors:  Qingfu Zhu; Qiyang Zhang; Ning Zhang; Maojun Gong
Journal:  Anal Chim Acta       Date:  2017-05-06       Impact factor: 6.558

3.  Rapid point of care analyzer for the measurement of cyanide in blood.

Authors:  Jian Ma; Shin-Ichi Ohira; Santosh K Mishra; Mahitti Puanngam; Purnendu K Dasgupta; Sari B Mahon; Matthew Brenner; William Blackledge; Gerry R Boss
Journal:  Anal Chem       Date:  2011-05-10       Impact factor: 6.986

4.  Cobinamide chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide.

Authors:  Jian Ma; Purnendu K Dasgupta; Felix H Zelder; Gerry R Boss
Journal:  Anal Chim Acta       Date:  2012-06-04       Impact factor: 6.558

5.  A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

Authors:  Qiyang Zhang; Naveen Maddukuri; Maojun Gong
Journal:  J Chromatogr A       Date:  2015-08-28       Impact factor: 4.759

Review 6.  Cyanides in the environment-analysis-problems and challenges.

Authors:  Ewa Jaszczak; Żaneta Polkowska; Sylwia Narkowicz; Jacek Namieśnik
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-16       Impact factor: 4.223

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.