Literature DB >> 17057970

Determination of nitrobenzene in wastewater using a hanging mercury drop electrode.

Shu-Xuan Liang1, Huan-Kun Zhang, Da Lu.   

Abstract

The determination of trace amount nitrobenzene in wastewater on a hanging mercury drop electrode was studied. The determination conditions of pH, supporting electrolyte, accumulation potential, accumulation time, and voltammetric response were optimized. The sharp peak of the nitrobenzene was appeared at 0.05 V. The peak electric current was proportional to the concentration of nitrobenzene in the range of 1.47 x 10(-5) approximately 1.0 x 10(-3) mol/l with relative standard deviations of 3.99 approximately 8.94%. The detection limit of the nitrobenzene in water was 5 x 10(-6) mol/l. The proposed method offered low limit of determination, easy operation, the use of simple instrumentation, high sensitivity and good reproducibility. It was applied to the determination of nitrobenzene in wastewater with an average recovery of 94.0% approximately 105%. The proposed method provided fast, sensitive and sometimes real time detection of nitrobenzene.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17057970     DOI: 10.1007/s10661-006-9366-7

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   3.307


  5 in total

1.  Hybrid reactor for priority pollutant nitrobenzene removal.

Authors:  Partha Sarathi Majumder; S K Gupta
Journal:  Water Res       Date:  2003-11       Impact factor: 11.236

2.  Studies on the sorption behaviors of nitrobenzene on marine sediments.

Authors:  Xue-Kun Zhao; Gui-Peng Yang; Xian-Chi Gao
Journal:  Chemosphere       Date:  2003-08       Impact factor: 7.086

3.  Separation and determination of nitrobenzenes by micellar electrokinetic chromatography and high-performance liquid chromatography.

Authors:  Shu-Ping Wang; Hwei-Jun Chen
Journal:  J Chromatogr A       Date:  2002-12-06       Impact factor: 4.759

4.  Voltammetric determination of 4-nitrophenol at a sodium montmorillonite-anthraquinone chemically modified glassy carbon electrode.

Authors:  S Hu; C Xu; G Wang; D Cui
Journal:  Talanta       Date:  2001-03-30       Impact factor: 6.057

5.  Preconcentration with membrane cell and adsorptive polarographic determination of phenols in air.

Authors:  Z Q Zhang; H Zhang; Q Deng
Journal:  Talanta       Date:  2000-12-04       Impact factor: 6.057

  5 in total
  2 in total

1.  Simultaneous polarographic determination of 2-nitrophenol and 4-nitrophenol by differential pulse polarography method and support vector regression.

Authors:  Karim Asadpour-Zeynali; Payam Soheili-Azad
Journal:  Environ Monit Assess       Date:  2011-04-12       Impact factor: 2.513

2.  Simultaneous determination of hydroxylamine and phenol using a nanostructure-based electrochemical sensor.

Authors:  Hadi Mahmoudi Moghaddam; Hadi Beitollahi; Somayeh Tajik; Mohammad Malakootian; Hassan Karimi Maleh
Journal:  Environ Monit Assess       Date:  2014-07-16       Impact factor: 2.513

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.