Literature DB >> 17056913

Effect of temporal subtraction technique on interpretation time and diagnostic accuracy of chest radiography.

Shingo Kakeda1, Koji Kamada, Yoshihisa Hatakeyama, Takatoshi Aoki, Yukunori Korogi, Shigehiko Katsuragawa, Kunio Doi.   

Abstract

OBJECTIVE: Our purpose was to compare reviewing time and diagnostic accuracy in the interpretation of radiographs without and with subtraction images and to examine whether this temporal subtraction technique can contribute to improving radiologists' performance.
MATERIALS AND METHODS: Thirty cases with newly developed chest abnormalities on chest radiographs and 90 negative cases were selected. All chest radiographs were obtained with a computed radiography system. For the 90 negative cases, subtraction images were classified into two groups: 33 clean images without misregistration artifacts and 57 images with some misregistration artifacts. Eight radiologists (four board-certified radiologists and four radiology residents) participated in observer tests and interpreted the original radiographs without and with subtraction images using an independent test method. The reviewing time for each radiologist was recorded in each case. The observers' performance was evaluated by use of receiver operating characteristic (ROC) analysis.
RESULTS: When subtraction images were available, the mean reviewing time per case was reduced significantly from 13.6 to 10.8 seconds for the cases with newly developed abnormalities (p < 0.001) and from 29.8 to 14.1 seconds for negative cases (p < 0.001). The reduction in the mean reviewing time with subtraction images was greater for clean images than for images with artifacts (17.7 vs 14.5 seconds, p < 0.001). The average mean area under the ROC curve value increased significantly from 0.942 without subtraction images to 0.988 with subtraction images (p = 0.025). There were significant differences in the sensitivity (0.963 with and 0.888 without the subtraction images) and the specificity (0.976 with and 0.899 without the subtraction images) (p < 0.001).
CONCLUSION: The temporal subtraction technique can reduce reviewing time and also improve diagnostic accuracy in the interpretation of chest radiographs.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17056913     DOI: 10.2214/AJR.05.1270

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

2.  Development of a voxel-matching technique for substantial reduction of subtraction artifacts in temporal subtraction images obtained from thoracic MDCT.

Authors:  Yoshinori Itai; Hyoungseop Kim; Seiji Ishikawa; Shigehiko Katsuragawa; Kunio Doi
Journal:  J Digit Imaging       Date:  2008-11-20       Impact factor: 4.056

3.  Small lung cancers: improved detection by use of bone suppression imaging--comparison with dual-energy subtraction chest radiography.

Authors:  Feng Li; Roger Engelmann; Lorenzo L Pesce; Kunio Doi; Charles E Metz; Heber Macmahon
Journal:  Radiology       Date:  2011-09-23       Impact factor: 11.105

4.  Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system.

Authors:  Yasuo Sasaki; Katsumi Abe; Makiko Tabei; Shigehiko Katsuragawa; Atsuko Kurosaki; Shoji Matsuoka
Journal:  Radiol Phys Technol       Date:  2010-12-18

5.  3D reconstruction of the human rib cage from 2D projection images using a statistical shape model.

Authors:  Jalda Dworzak; Hans Lamecker; Jens von Berg; Tobias Klinder; Cristian Lorenz; Dagmar Kainmüller; Heiko Seim; Hans-Christian Hege; Stefan Zachow
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-07-26       Impact factor: 2.924

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.