Literature DB >> 17056901

Inguinofemoral hernia: accuracy of sonography in patients with indeterminate clinical features.

Philip Robinson1, Elizabeth Hensor, Mark J Lansdown, N Simon Ambrose, Anthony H Chapman.   

Abstract

OBJECTIVE: The objective of our study was to investigate the accuracy of sonography in patients with symptoms suggestive of a hernia and normal or equivocal clinical examination findings. SUBJECTS AND METHODS: Fifty-nine consecutive patients (47 men, 12 women; median age, 51 years; range, 19-82 years) were enrolled in a prospective study of sonography and herniography for investigation of inguinofemoral pain. All patients were referred with a history suggestive of hernia but with equivocal clinical features by three experienced surgeons. All patients underwent sonography and herniography examinations performed by experienced radiologists blinded to clinical details. The imaging variables recorded for each side were normal (including posterior inguinal wall bulging), hernia (indirect, direct, femoral, and abdominal wall), or nondiagnostic. The percentage of exact agreement, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for sonography and herniography and were compared with surgery when performed; then all sides for sonography were compared with herniography.
RESULTS: Surgery was performed in 18 patients (31%) on 21 sides and found hernia (n = 20) and patulous posterior inguinal wall (with no hernia) (n = 1). Compared with surgery, the results of sonography versus herniography, respectively, were exact agreement (91% vs 71%), sensitivity (95% vs 70%), specificity (100% vs 100%), PPV (100% vs 100%), and NPV (50% vs 14%). The sensitivity of sonography was significantly higher than that of herniography (McNemar test, p = 0.025). Both techniques had one false-negative in the same patient. Herniography had five additional false-negatives identified as hernias at sonography and surgery. Compared with herniography as the reference, the sonography findings were in exact agreement in 91% (107/118) of the cases; and sensitivity was 90% (19/21); specificity, 91% (88/97); PPV, 68% (19/28); and NPV, 98% (88/90).
CONCLUSION: Sonography is an accurate technique for the detection of inguinofemoral hernias in patients with clinically equivocal findings.

Entities:  

Mesh:

Year:  2006        PMID: 17056901     DOI: 10.2214/AJR.05.1251

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  17 in total

1.  Evaluation of the usage and influence of groin ultrasound in primary and secondary healthcare settings.

Authors:  B Kim; P Robinson; H Modi; H Gupta; K Horgan; R Achuthan
Journal:  Hernia       Date:  2014-01-10       Impact factor: 4.739

Review 2.  A systematic review and meta-analysis of the role of radiology in the diagnosis of occult inguinal hernia.

Authors:  Amy Robinson; Duncan Light; Adetayo Kasim; Colin Nice
Journal:  Surg Endosc       Date:  2012-06-26       Impact factor: 4.584

3.  Evaluation of dynamic ultrasound scanning in the diagnosis of equivocal ventral hernias with surgical comparison.

Authors:  Prem Ruben Jayaram; Fatima DA Pereira; James A Barrett
Journal:  Br J Radiol       Date:  2018-06-01       Impact factor: 3.039

4.  The accuracy of ultrasonography in classification of groin hernias according to the criteria of the unified classification system.

Authors:  A Djuric-Stefanovic; D Saranovic; A Ivanovic; D Masulovic; M Zuvela; M Bjelovic; P Pesko
Journal:  Hernia       Date:  2008-02-22       Impact factor: 4.739

5.  Ultrasonography in diagnosing clinically occult groin hernia: systematic review and meta-analysis.

Authors:  Robert M Kwee; Thomas C Kwee
Journal:  Eur Radiol       Date:  2018-05-14       Impact factor: 5.315

6.  European Hernia Society guidelines on the treatment of inguinal hernia in adult patients.

Authors:  M P Simons; T Aufenacker; M Bay-Nielsen; J L Bouillot; G Campanelli; J Conze; D de Lange; R Fortelny; T Heikkinen; A Kingsnorth; J Kukleta; S Morales-Conde; P Nordin; V Schumpelick; S Smedberg; M Smietanski; G Weber; M Miserez
Journal:  Hernia       Date:  2009-07-28       Impact factor: 4.739

7.  A rare and frequently unrecognised pathology in children: femoral hernia.

Authors:  A Temiz; B Akcora; M Temiz; E Canbolant
Journal:  Hernia       Date:  2008-03-11       Impact factor: 4.739

8.  International guidelines for groin hernia management.

Authors: 
Journal:  Hernia       Date:  2018-01-12       Impact factor: 4.739

9.  Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results.

Authors:  Tanja Fischer; Roland Ladurner; Alexander Gangkofer; Thomas Mussack; Maximilian Reiser; Andreas Lienemann
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

10.  Sonographic "speech bubble/speech box sign" in clinically occult femoral hernias: ultrasound findings and anatomical basis.

Authors:  Siddharth Thaker; Rajesh Botchu; Harun Gupta
Journal:  J Ultrasound       Date:  2020-06-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.