Embolic stroke due to a left atrial thrombus two years after placement of an atrial septal defect closure device.

Aarti Raghu1, Darryl Kawalsky, Mark Feldman.   

Abstract

A 29-year-old woman who had undergone closure of a secundum-type atrial septal defect using the Amplatzer device 2 years previously developed acute and progressive altered mentation. Initial clinical and imaging data confirmed the diagnosis of multiple cerebral, cerebellar and brain stem emboli, and infarcts. She was treated urgently with an intra-arterial thrombolytic agent with only minimal improvement. Transesophageal echocardiography revealed a large thrombus attached to the left atrial disc of the atrial septal defect occluder, which was the source of the emboli. In conclusion, this is the first reported case, to our knowledge, of disseminated cerebral emboli and infarctions as a late complication of transcatheter closure of a secundum-type atrial septal defect.

Entities:  

Mesh:

Year:  2006        PMID: 17056350     DOI: 10.1016/j.amjcard.2006.05.067

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

Review 1.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

Review 2.  Stroke and peripheral embolism from an Amplatzer septal occluder 5 years after implantation.

Authors:  Claudia Stöllberger; Josef Finsterer; Elisabeth Krexner; Birke Schneider
Journal:  J Neurol       Date:  2008-06-13       Impact factor: 4.849

3.  Analysis of the US Food and Drug Administration Manufacturer and User Facility Device Experience database for adverse events involving Amplatzer septal occluder devices and comparison with the Society of Thoracic Surgery congenital cardiac surgery database.

Authors:  Daniel J DiBardino; Doff B McElhinney; Aditya K Kaza; John E Mayer
Journal:  J Thorac Cardiovasc Surg       Date:  2009-06       Impact factor: 5.209

4.  Angioscopic Evaluation of Atrial Septal Defect Closure Device Neo-Endothelialization.

Authors:  Yasuhiro Tanabe; Tomomi Suzuki; Shingo Kuwata; Masaki Izumo; Hiromasa Kawaguchi; Shun Ogoda; Nozomi Kotoku; Yukio Sato; Haruka Nishikawa; Toshiki Kaihara; Masashi Koga; Takanobu Mitarai; Kazuaki Okuyama; Ryo Kamijima; Yuki Ishibashi; Kihei Yoneyama; Takumi Higuma; Tomoo Harada; Yoshihiro J Akashi
Journal:  J Am Heart Assoc       Date:  2021-09-17       Impact factor: 5.501

Review 5.  Amplatzer Patent Foramen Ovale Occluder Device-Related Complications.

Authors:  Beshoy Iskander; Fatima Anwer; Federico Oliveri; Kakargias Fotios; Priyanka Panday; Ana P Arcia Franchini; Pousette Hamid
Journal:  Cureus       Date:  2022-04-02

6.  Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect.

Authors:  Ah Young Kim; Wongi Woo; Beom Jin Lim; Jo Won Jung; Jae Young Choi; Young Jin Kim
Journal:  Circ Cardiovasc Imaging       Date:  2022-07-19       Impact factor: 8.589

  6 in total