Literature DB >> 17056200

Impact of intra-arterial administration of boron compounds on dose-volume histograms in boron neutron capture therapy for recurrent head-and-neck tumors.

Minoru Suzuki1, Yoshinori Sakurai, Kenji Nagata, Yuko Kinashi, Shinichiro Masunaga, Koji Ono, Akira Maruhashi, Ituro Kato, Nobukazu Fuwa, Junichi Hiratsuka, Yoshio Imahori.   

Abstract

PURPOSE: To analyze the dose-volume histogram (DVH) of head-and-neck tumors treated with boron neutron capture therapy (BNCT) and to determine the advantage of the intra-arterial (IA) route over the intravenous (IV) route as a drug delivery system for BNCT. METHODS AND MATERIALS: Fifteen BNCTs for 12 patients with recurrent head-and-neck tumors were included in the present study. Eight irradiations were done after IV administration of boronophenylalanine and seven after IA administration. The maximal, mean, and minimal doses given to the gross tumor volume were assessed using a BNCT planning system.
RESULTS: The results are reported as median values with the interquartile range. In the IA group, the maximal, mean, and minimal dose given to the gross tumor volume was 68.7 Gy-Eq (range, 38.8-79.9), 45.0 Gy-Eq (range, 25.1-51.0), and 13.8 Gy-Eq (range, 4.8-25.3), respectively. In the IV group, the maximal, mean, and minimal dose given to the gross tumor volume was 24.2 Gy-Eq (range, 21.5-29.9), 16.4 Gy-Eq (range, 14.5-20.2), and 7.8 Gy-Eq (range, 6.8-9.5), respectively. Within 1-3 months after BNCT, the responses were assessed. Of the 6 patients in the IV group, 2 had a partial response, 3 no change, and 1 had progressive disease. Of 4 patients in the IA group, 1 achieved a complete response and 3 a partial response.
CONCLUSION: Intra-arterial administration of boronophenylalanine is a promising drug delivery system for head-and-neck BNCT.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17056200     DOI: 10.1016/j.ijrobp.2006.07.1373

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

Review 1.  Boron neutron capture therapy (BNCT): a unique role in radiotherapy with a view to entering the accelerator-based BNCT era.

Authors:  Minoru Suzuki
Journal:  Int J Clin Oncol       Date:  2019-06-05       Impact factor: 3.402

Review 2.  Boron delivery agents for neutron capture therapy of cancer.

Authors:  Rolf F Barth; Peng Mi; Weilian Yang
Journal:  Cancer Commun (Lond)       Date:  2018-06-19

Review 3.  Clinical trials for treating recurrent head and neck cancer with boron neutron capture therapy using the Tsing-Hua Open Pool Reactor.

Authors:  Ling-Wei Wang; Yen-Wan Hsueh Liu; Fong-In Chou; Shiang-Huei Jiang
Journal:  Cancer Commun (Lond)       Date:  2018-06-19

4.  A comparison of dose distributions in gross tumor volume between boron neutron capture therapy alone and combined boron neutron capture therapy plus intensity modulation radiation therapy for head and neck cancer.

Authors:  Jia-Cheng Lee; Keh-Shih Chuang; Yen-Wan Hsueh Liu; Tzung-Yi Lin; Yi-Chiao Teng; Ling-Wei Wang
Journal:  PLoS One       Date:  2019-04-04       Impact factor: 3.240

Review 5.  Boron Neutron Capture Therapy: A Review of Clinical Applications.

Authors:  Timothy D Malouff; Danushka S Seneviratne; Daniel K Ebner; William C Stross; Mark R Waddle; Daniel M Trifiletti; Sunil Krishnan
Journal:  Front Oncol       Date:  2021-02-26       Impact factor: 6.244

Review 6.  Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer.

Authors:  Rolf F Barth; M Graca H Vicente; Otto K Harling; W S Kiger; Kent J Riley; Peter J Binns; Franz M Wagner; Minoru Suzuki; Teruhito Aihara; Itsuro Kato; Shinji Kawabata
Journal:  Radiat Oncol       Date:  2012-08-29       Impact factor: 3.481

  6 in total