Contaminated oral intubation equipment associated with an outbreak of carbapenem-resistant Pseudomonas in an intensive care unit.

T Kikuchi1, G Nagashima, K Taguchi, H Kuraishi, H Nemoto, M Yamanaka, R Kawano, K Ugajin, S Tazawa, K Marumo.   

Abstract

Twenty intensive care patients were diagnosed as infected or colonized by Pseudomonas aeruginosa within a one-month period; a rate three to four times higher than the typical background frequency of this infection in the intensive care unit (ICU). Patients with positive respiratory specimens were mechanically ventilated, which included re-used disinfected bite blocks during intubation. Fourteen specimens from 20 positive patients originated in the respiratory tract. Seven clonal variants were isolated and identified as originating from the same strain by pulsed-field analysis. These isolates were also matched to the strain detected on the re-used bite blocks, which had been disinfected with 140ppm sodium hydrochloride. Notably, Staphylococcus aureus was also detected on bite blocks sterilized with ethylene dioxide, indicating incomplete disinfection. In immunocompromised patients, re-use of bite blocks during intubation must be prohibited. Single-use kits or intubation without the use of bite blocks is recommended.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17055113     DOI: 10.1016/j.jhin.2006.07.017

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  3 in total

1.  Wide dispersion of ST175 clone despite high genetic diversity of carbapenem-nonsusceptible Pseudomonas aeruginosa clinical strains in 16 Spanish hospitals.

Authors:  María García-Castillo; Rosa Del Campo; María Isabel Morosini; Elena Riera; Gabriel Cabot; Rob Willems; Rosa van Mansfeld; Antonio Oliver; Rafael Cantón
Journal:  J Clin Microbiol       Date:  2011-06-22       Impact factor: 5.948

Review 2.  A systematic review and meta-analyses show that carbapenem use and medical devices are the leading risk factors for carbapenem-resistant Pseudomonas aeruginosa.

Authors:  Anne F Voor In 't Holt; Juliëtte A Severin; Emmanuel M E H Lesaffre; Margreet C Vos
Journal:  Antimicrob Agents Chemother       Date:  2014-02-18       Impact factor: 5.191

3.  IMP-38-Producing High-Risk Sequence Type 307 Klebsiella pneumoniae Strains from a Neonatal Unit in China.

Authors:  Siyi Wang; Juan Zhao; Ning Liu; Fang Yang; Yiming Zhong; Xiumei Gu; Zijuan Jian; Qun Yan; Qingxia Liu; Hongling Li; Yanming Li; Jing Liu; Hui Li; Liang Chen; Wenen Liu
Journal:  mSphere       Date:  2020-07-01       Impact factor: 4.389

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.