Literature DB >> 17053152

Rapid and simultaneous quantification of 4 urinary proteins by piezoelectric quartz crystal microbalance immunosensor array.

Yang Luo1, Ming Chen, Qianjun Wen, Meng Zhao, Bo Zhang, Xiaoyan Li, Feng Wang, Qing Huang, Chunyan Yao, Tianlun Jiang, Guoru Cai, Weiling Fu.   

Abstract

BACKGROUND: Urinary proteins are predictive and prognostic markers for diabetes nephropathy. Conventional methods for the quantification of urinary proteins, however, are time-consuming, and most require radioactive labeling. We designed a label-free piezoelectric quartz crystal microbalance (QCM) immunosensor array to simultaneously quantify 4 urinary proteins.
METHODS: We constructed a 2 x 5 model piezoelectric immunosensor array fabricated with disposable quartz crystals for quantification of microalbumin, alpha1-microglobulin, beta2-microglobulin, and IgG in urine. We made calibration curves after immobilization of antibodies at an optimal concentration and then evaluated the performance characteristics of the immunosensor with a series of tests. In addition, we measured 124 urine samples with both QCM immunosensor array and immunonephelometry to assess the correlation between the 2 methods.
RESULTS: With the QCM immunosensor array, we were able to quantify 4 urinary proteins within 15 min. This method had an analytical interval of 0.01-60 mg/L. The intraassay and interassay imprecisions (CVs) were <10%, and the relative recovery rates were 90.3%-109.1%. Nonspecificity of the immunosensor was insignificant (frequency shifts <20 Hz). ROC analyses indicated sensitivities were > or =95.8% and, specificities were > or =76.3%. Bland-Altman difference plots showed the immunosensor array to be highly comparable to immunonephelometry.
CONCLUSIONS: The QCM system we designed has the advantages of being rapid, label free, and highly sensitive and thus can be a useful supplement to commercial assay methods in clinical chemistry.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17053152     DOI: 10.1373/clinchem.2006.073569

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  8 in total

Review 1.  Antibody-based protein multiplex platforms: technical and operational challenges.

Authors:  Allison A Ellington; Iftikhar J Kullo; Kent R Bailey; George G Klee
Journal:  Clin Chem       Date:  2009-12-03       Impact factor: 8.327

2.  Rapid label-free identification of mixed bacterial infections by surface plasmon resonance.

Authors:  Jue Wang; Yang Luo; Bo Zhang; Ming Chen; Junfu Huang; Kejun Zhang; Weiyin Gao; Weiling Fu; Tianlun Jiang; Pu Liao
Journal:  J Transl Med       Date:  2011-06-07       Impact factor: 5.531

3.  Early TBI-Induced Cytokine Alterations are Similarly Detected by Two Distinct Methods of Multiplex Assay.

Authors:  Sanjib Mukherjee; Khurshed Katki; Gabriel M Arisi; Maira L Foresti; Lee A Shapiro
Journal:  Front Mol Neurosci       Date:  2011-09-16       Impact factor: 5.639

4.  Development of a quartz crystal microbalance biosensor with aptamers as bio-recognition element.

Authors:  Chunyan Yao; Tangyou Zhu; Yongzhi Qi; Yuhui Zhao; Han Xia; Weiling Fu
Journal:  Sensors (Basel)       Date:  2010-06-09       Impact factor: 3.576

5.  Fe₃O₄/Au magnetic nanoparticle amplification strategies for ultrasensitive electrochemical immunoassay of alfa-fetoprotein.

Authors:  Ning Gan; Haijuan Jin; Tianhua Li; Lei Zheng
Journal:  Int J Nanomedicine       Date:  2011-12-09

6.  Surface enhanced Raman scattering artificial nose for high dimensionality fingerprinting.

Authors:  Nayoung Kim; Michael R Thomas; Mads S Bergholt; Isaac J Pence; Hyejeong Seong; Patrick Charchar; Nevena Todorova; Anika Nagelkerke; Alexis Belessiotis-Richards; David J Payne; Amy Gelmi; Irene Yarovsky; Molly M Stevens
Journal:  Nat Commun       Date:  2020-01-10       Impact factor: 14.919

Review 7.  Bulk and Surface Acoustic Wave Sensor Arrays for Multi-Analyte Detection: A Review.

Authors:  Kerstin Länge
Journal:  Sensors (Basel)       Date:  2019-12-06       Impact factor: 3.576

8.  Label-Free Protein Detection by Micro-Acoustic Biosensor Coupled with Electrical Field Sorting. Theoretical Study in Urine Models.

Authors:  Nikolay Mukhin; Georgii Konoplev; Aleksandr Oseev; Marc-Peter Schmidt; Oksana Stepanova; Andrey Kozyrev; Alexander Dmitriev; Soeren Hirsch
Journal:  Sensors (Basel)       Date:  2021-04-06       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.