Literature DB >> 17052555

Real-time ultrasonographically-guided internal jugular vein catheterization in the emergency department increases success rates and reduces complications: a randomized, prospective study.

Julie Leung1, Martin Duffy, Andrew Finckh.   

Abstract

STUDY
OBJECTIVE: We compare real-time ultrasonographic guidance and the traditional landmark technique for the insertion of internal jugular vein catheters in an emergency department (ED) setting.
METHODS: This was a prospective, randomized, clinical study performed in a tertiary ED between August 2003 and May 2005 on patients requiring central venous access. Ultrasonographically guided catheters were inserted under real time using the Sonosite ultrasonographic system with a 10 to 5 MHz 38-mm linear array transducer. Standardized data were collected on operator experience, method of insertion, reason for central venous access, and comorbidities. Outcome measures included successful insertion of an internal jugular vein catheter, number of attempts, access times, and complications.
RESULTS: One hundred thirty patients were enrolled. Cannulation of the internal jugular vein was successful in 61 of 65 patients (93.9%) using ultrasonography and in 51 of 65 patients (78.5%) using the landmark technique, a significant difference of 15.4% (P=.009, 95% confidence interval [CI] 3.8% to 27.0%). Fifty of 61 (82.0%) of the successful ultrasonographically guided catheters were inserted on the first attempt compared with 36 of 51 (70.6%) of the successful landmark catheters. Mean access times to venipuncture and successful insertion were 138 and 281 seconds by ultrasonographic guidance and 132 and 271 seconds by the landmark technique. There was a 10.8% complication rate, with 11 complications (16.9%) in the landmark group and 3 (4.6%) in the ultrasonographic group, a difference of 12.3% (95% CI 1.9% to 22.8%).
CONCLUSION: Ultrasonographically guided internal jugular vein catheterization in the ED setting was associated with a higher successful insertion rate and a lower complications rate.

Entities:  

Mesh:

Year:  2006        PMID: 17052555     DOI: 10.1016/j.annemergmed.2006.01.011

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  64 in total

1.  Simulation-based training improves applied clinical placement of ultrasound-guided PICCs.

Authors:  Pamela Andreatta; Yifang Chen; Michael Marsh; Kyung Cho
Journal:  Support Care Cancer       Date:  2010-03-20       Impact factor: 3.603

2.  Comparison of intraosseous access and central venous catheterization in Chinese adult emergency patients: A prospective, multicenter, and randomized study.

Authors:  Yan-Yan Liu; Yu-Peng Wang; Ling-Yun Zu; Kang Zheng; Qing-Bian Ma; Ya-An Zheng; Wei Gao
Journal:  World J Emerg Med       Date:  2021

Review 3.  International evidence-based recommendations on ultrasound-guided vascular access.

Authors:  Massimo Lamperti; Andrew R Bodenham; Mauro Pittiruti; Michael Blaivas; John G Augoustides; Mahmoud Elbarbary; Thierry Pirotte; Dimitrios Karakitsos; Jack Ledonne; Stephanie Doniger; Giancarlo Scoppettuolo; David Feller-Kopman; Wolfram Schummer; Roberto Biffi; Eric Desruennes; Lawrence A Melniker; Susan T Verghese
Journal:  Intensive Care Med       Date:  2012-05-22       Impact factor: 17.440

Review 4.  Echocardiographic guidance for diagnostic and therapeutic percutaneous procedures.

Authors:  Cam Tu Nguyen; Eunice Lee; Huai Luo; Robert J Siegel
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

5.  Risk factors for acute adverse events during ultrasound-guided central venous cannulation in the emergency department.

Authors:  Daniel Theodoro; Missy Krauss; Marin Kollef; Bradley Evanoff
Journal:  Acad Emerg Med       Date:  2010-10       Impact factor: 3.451

Review 6.  [New KDIGO guidelines on acute kidney injury. Practical recommendations].

Authors:  A Zarbock; S John; A Jörres; D Kindgen-Milles
Journal:  Anaesthesist       Date:  2014-07       Impact factor: 1.041

7.  Theme-based teaching of point-of-care ultrasound in undergraduate medical education.

Authors:  Richard Amini; Lori Ann Stolz; Austin Gross; Kathleen O'Brien; Ashish Raman Panchal; Kevin Reilly; Lisa Chan; Brian Scott Drummond; Arthur Sanders; Srikar Adhikari
Journal:  Intern Emerg Med       Date:  2015-03-13       Impact factor: 3.397

8.  Impact of ultrasonography on central venous catheter insertion in intensive care.

Authors:  Gopal B Palepu; Juneja Deven; M Subrahmanyam; S Mohan
Journal:  Indian J Radiol Imaging       Date:  2009 Jul-Sep

9.  The polony phantom: a cost-effective aid for teaching emergency ultrasound procedures.

Authors:  Mike Wells; Lara Goldstein
Journal:  Int J Emerg Med       Date:  2010-03-30

10.  Is the intraosseous access route fast and efficacious compared to conventional central venous catheterization in adult patients under resuscitation in the emergency department? A prospective observational pilot study.

Authors:  Bernd A Leidel; Chlodwig Kirchhoff; Viktoria Bogner; Julia Stegmaier; Wolf Mutschler; Karl-Georg Kanz; Volker Braunstein
Journal:  Patient Saf Surg       Date:  2009-10-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.