Literature DB >> 17052038

Third-generation vs a second-generation LED curing light: effect on Knoop microhardness.

Richard B T Price1, Corey A Felix, Pantelis Andreou.   

Abstract

Third-generation light-emitting diode (LED) curing lights use several different types of LEDs within the light to deliver a broader spectral output compared with the narrower spectral output of second-generation curing lights. This study determined the benefits of this broader spectral output. A third-generation LED curing light was modified so that the 4 peripheral LEDs, which provide the lower wavelengths, could be turned on or off, allowing the light to be used as a third- or a second-generation LED curing light. Twelve composites of A2 and lighter shades were packed into molds 2 mm deep with an internal diameter of 12 mm, and then irradiated for 20 seconds. A laboratory-grade spectroradiometer was used to ensure that all the specimens received the same irradiance and total energy (16.82 J/cm2) from the curing light in both the second- and third-generation modes. The results showed the benefits of using a broader spectrum third-generation LED curing light. This light produced composites that were as hard as when the narrower spectrum second-generation LED curing light was used (P < or = .01). In 7 of the 12 resin composites, the top surface was harder when the third-generation LED curing light was used (P < or = .01).

Mesh:

Substances:

Year:  2006        PMID: 17052038

Source DB:  PubMed          Journal:  Compend Contin Educ Dent        ISSN: 1548-8578


  6 in total

1.  Curing effectiveness of single-peak and multi-peak led light curing units on tpo-containing resin composites with different chromatic characteristics.

Authors:  G Conte; M Panetta; M Mancini; A Fabianelli; A Brotzu; R Sorge; L Cianconi
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

2.  Curing efficacy of light emitting diodes of dental curing units.

Authors:  Seyed Mostafa Mousavinasab; Ian Meyers
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2009-03-16

3.  Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite.

Authors:  Kelly Antonieta Oliveira Rodrigues de Faria Cardoso; Driellen Christine Zarpellon; Camila Ferreira Leite Madruga; José Augusto Rodrigues; Cesar Augusto Galvão Arrais
Journal:  J Appl Oral Sci       Date:  2017 Mar-Apr       Impact factor: 2.698

Review 4.  Utilizing Light Cure Units: A Concise Narrative Review.

Authors:  Fatin A Hasanain; Hani M Nassar
Journal:  Polymers (Basel)       Date:  2021-05-15       Impact factor: 4.329

5.  Does an additional UV LED improve the degree of conversion and Knoop Hardness of light-shade composite resins?

Authors:  Maria Cecília Caldas Giorgi; Flávio Henrique Baggio Aguiar; Luís Eduardo Silva Soares; Airton Abrahão Martin; Priscila Christiane Suzy Liporoni; Luís Alexandre Maffei Sartini Paulillo
Journal:  Eur J Dent       Date:  2012-10

6.  Effects of delivering the same radiant exposures at 730, 1450, and 2920 mW/cm2 to two resin-based composites.

Authors:  Maan M AlShaafi
Journal:  Eur J Dent       Date:  2017 Jan-Mar
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.