Literature DB >> 17049875

Should a reimplantation valve sparing procedure be done systematically in type A aortic dissection?

Fadi Farhat1, Marion Durand, Loïc Boussel, Ingrid Sanchez, Jacques Villard, Olivier Jegaden.   

Abstract

OBJECTIVE: To evaluate the risks and benefits of a systematic reimplantation valve sparing procedure in the surgical treatment of type A aortic dissection (TAAD). PATIENTS AND METHODS: From February December 2005, 15 consecutive patients (mean age 61+/-12 years) who underwent surgery for TAAD were analyzed prospectively. Eleven had a preoperative CT-scan and all had an echography. Eight patients presented with a preoperative aortic insufficiency>2/4 and seven had an ascending aortic aneurysm over 50mm. In 11 cases, arterial cannulation was performed directly into the ascending aorta. Surgical technique included complete resection and replacement of the ascending aorta using a reimplantation valve sparing technique (David), associated in 12 patients with an arch replacement, under mild (29.7+/-3.0 degrees C) hypothermia and cerebral selective antegrade perfusion.
RESULTS: Aortic clamping, cerebral perfusion and cardiopulmonary bypass (CPB) times were respectively 93+/-29, 18+/-9, and 131+/-38min. Mean bleeding at 24h was 1165+/-846ml. Troponin I level at 24h was 21+/-30 microg/l. One patient had a right coronary artery bypass for a chronically occluded coronary. Another had a triple arterial revascularisation for pre-existing coronary dissection. One patient presented with a postoperative regressive right hemiparesia (normal CT-scan). Two patients underwent revision for bleeding (one was undergoing treatment by clopidogrel). One patient had at day 7 an implantation of a covered stentgraft on the descending aorta for a concomitant penetrating aortic ulcer. One patient died suddenly on POD 7 during a tracheal aspiration. Intubation and ICU times were respectively 9.5+/-16.3 and 16.2+/-20.9 days. Four patients with severe preoperative co morbidities had long intubations. Echographic and CT-scan control, done in postoperative and after a mean follow up of 11.0+/-4.8 months, did not show any residual aortic insufficiency (actuarial survival rate at 2 years of 93.3%).
CONCLUSION: A reimplantation valve sparing procedure in the TAAD seems to be reliable and should be proposed systematically without emphasizing perioperative morbidity.

Entities:  

Mesh:

Year:  2006        PMID: 17049875     DOI: 10.1016/j.ejcts.2006.09.018

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  2 in total

Review 1.  An update on surgery for acute type A aortic dissection: aortic root repair, endovascular stent graft, and genetic research.

Authors:  Shinichi Suzuki; Munetaka Masuda
Journal:  Surg Today       Date:  2009-03-25       Impact factor: 2.549

2.  Partial root remodeling on the two sinuses for acute type a aortic dissection with right coronary arterial dissection.

Authors:  Akira Katayama; Naomichi Uchida; Miwa Sutoh; Taijiro Sueda
Journal:  Ann Vasc Dis       Date:  2013-09-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.