Literature DB >> 17046702

Frequency doubling technology perimetry in normal children.

Laurel M Quinn1, Stuart K Gardiner, David T Wheeler, Michelle Newkirk, Chris A Johnson.   

Abstract

PURPOSE: To test visual field thresholds of normal children with frequency doubling technology (FDT) perimetry to quantify testing times and reliability characteristics in a pediatric population and to determine whether current methods of stratifying adult threshold values need revision for children.
DESIGN: Prospective cross-sectional study.
METHODS: Ninety-four children, ages 5 to 17 years, were recruited from local pediatric clinics and the general community and were tested at one center. Children likely to have abnormal visual fields or abnormal test taking ability because of ophthalmic, neurologic, or behavioral problems were excluded. Children were asked to perform a threshold FDT visual field with each of their eyes. Threshold results were gathered, analyzed, and compared with the standards that have been established for tests in adults. Results were validated by testing a further 72 children, with the same protocol, at a different center.
RESULTS: For children older than 14 years, threshold mean deviation values were within normal limits according to the adult normative database that is used currently in FDT perimetry. Below 15 years of age, mean deviations for normal children decreased with decreasing age. The best linear fit was given by a mean deviation of -11.43 +/- 0.82 dB x age (R2 = 0.18; P < 10(-5)).
CONCLUSION: This research establishes a normative model for pediatric visual field testing with FDT and, by a comparison of threshold results for normal children to established adult norms, provides evidence that parameters for normal sensitivity must be revised for children younger than 15 years.

Entities:  

Mesh:

Year:  2006        PMID: 17046702     DOI: 10.1016/j.ajo.2006.06.067

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  3 in total

1.  Normal Threshold Size of Stimuli in Children Using a Game-Based Visual Field Test.

Authors:  Yanfang Wang; Zaria Ali; Siddharth Subramani; Susmito Biswas; Cecilia Fenerty; David B Henson; Tariq Aslam
Journal:  Ophthalmol Ther       Date:  2016-11-24

2.  Alzheimer's disease: screening biomarkers using frequency doubling technology visual field.

Authors:  Denise A Valenti
Journal:  ISRN Neurol       Date:  2013-09-25

3.  Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children.

Authors:  Sibel Kocabeyoglu; Salih Uzun; Mehmet Cem Mocan; Banu Bozkurt; Murat Irkec; Mehmet Orhan
Journal:  Indian J Ophthalmol       Date:  2013-10       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.