Literature DB >> 17046263

Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction.

Jae Chul Yoo1, Jin Hwan Ahn, Jae Hoon Kim, Byung Kwan Kim, Kui Won Choi, Tae Soo Bae, Chang Yang Lee.   

Abstract

Hamstring tendon using quadrupled semitendinosus and gracilis autografts is a well-established technique for ACL reconstruction. However, several methods have been used for tibial fixation of the tendon graft. The purpose of this study was to compare the biomechanical characteristics of quadrupled hamstring graft tibial fixation using three different fixation methods. Nine matched pairs (18 specimens) of cadaver tibias were divided into three groups of six specimens. The first group was fixed with only a tapered 30-mm bioabsorbable screw (BIS), the second group was fixed first with a BIS and then the remaining tendon portion was additionally fixed with a titanium cortical screw and spike washer, and the third group was fixed with only a cortical screw and spike washer. A custom-made probe hook was mounted on a load cell (Interface, MFG, Scottsdale, AZ) to measure the ACL tension before and after the final tibial fixation. Group 2 displayed greater mean maximum load at failure than both groups 1 and 3 (p<0.05). The stiffness of the graft nearly doubled in group 2 compared to groups 1 and 3 (p<0.05). All specimens failed by slippage and pullout. Biomechanical testing with cadavers showed that a BIS and additional cortical screw and spike washer fixation to the distal hamstring tendon resulted in higher load at failure and stiffness compared to either BIS or cortical screw and spike washer fixation alone.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17046263     DOI: 10.1016/j.knee.2006.08.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  5 in total

Review 1.  Graft healing in anterior cruciate ligament reconstruction.

Authors:  Max Ekdahl; James H-C Wang; Mario Ronga; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-07-17       Impact factor: 4.342

2.  A biomechanical comparison of the Delta screw and RetroScrew tibial fixation on initial intra-articular graft tension.

Authors:  Peter C Rhee; Bruce A Levy; Michael J Stuart; Andrew Thoreson; Kai-Nan An; Diane L Dahm
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-22       Impact factor: 4.342

3.  Comparison of bioabsorbable suture anchor fixation on the tibial side for anterior cruciate ligament reconstruction using free soft tissue graft: experimental laboratory study on porcine bone.

Authors:  Myung Ku Kim; Suk In Na; Jong Min Lee; Ju Yong Park
Journal:  Yonsei Med J       Date:  2014-04-01       Impact factor: 2.759

4.  Significant Loss of ACL Graft Force With Tibial-Sided Soft Tissue Interference Screw Fixation Over 24 Hours: A Biomechanical Study.

Authors:  Philipp Kruppa; Anne Flies; Dag Wulsten; Robert Collette; Georg N Duda; Klaus-Dieter Schaser; Roland Becker; Sebastian Kopf
Journal:  Orthop J Sports Med       Date:  2020-05-04

5.  The Proximal Tibia Loses Bone Mineral Density After Anterior Cruciate Ligament Injury: Measurement Technique and Validation of a Quantitative Computed Tomography Method.

Authors:  Erick M Marigi; David R Holmes; Naveen Murthy; Bruce A Levy; Michael J Stuart; Diane L Dahm; Peter C Rhee; Aaron J Krych
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-11-02
  5 in total