Literature DB >> 17045541

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

Tomás F Cianciulli1, Jorge A Lax, María C Saccheri, Robert Guidoin, César M Salvado, Adrián J Fernández, Horacio A Prezioso.   

Abstract

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Entities:  

Mesh:

Year:  2008        PMID: 17045541     DOI: 10.1016/j.euje.2006.08.018

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  3 in total

1.  Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

Authors:  Gaku Uchino; Hideo Yoshida; Naoya Sakoda; Shigeru Hattori; Takuya Kawabata; Munehiro Saiki; Yasufumi Fujita; Keiji Yunoki; Kunikazu Hisamochi; Yoshinari Mine
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-06-03

Review 2.  Valve-related complications after mechanical heart valve implantation.

Authors:  Yoshio Misawa
Journal:  Surg Today       Date:  2014-12-18       Impact factor: 2.549

3.  Spontaneous leaflet fracture resulting in embolization from mechanical valve prostheses.

Authors:  Gijs G J van Steenbergen; Queeny H Y Tsang; Stefan M van der Heide; Michel W A Verkroost; Wilson W L Li; Wim J Morshuis
Journal:  J Card Surg       Date:  2018-12-30       Impact factor: 1.620

  3 in total