Literature DB >> 17044407

Robust estimation of bioaffinity assay fluorescence signals.

Dimitris Glotsos1, Jussi Tohka, Jori Soukka, Juhani T Soini, Ulla Ruotsalainen.   

Abstract

In this paper, the challenging problem of robust mean-signal estimation of a single-step microparticle bioaffinity assay is investigated. For this purpose, a density estimation-based robust algorithm (DER) was developed. The DER algorithm was comparatively evaluated with four other parameter estimation methods (mean value, median filtering, least square estimation, Welsch robust m-estimator). Two important questions were raised and investigated: 1) Which of the five methods can robustly estimate the mean bioaffinity signal? and 2) How many microparticles need to be measured in order to obtain an accurate estimate of the mean signal value? To answer the questions, bootstrap and coefficient of variation (CV) analyses were performed. In the CV analysis, the DER algorithm gave the best results: The CV ranged from 0.8% to 4.9% when the number of microparticles used for the mean signal estimation varied from 800 to 30. In the bootstrap analysis of the standard error, the DER algorithm had the smallest variance. As a conclusion, it can be underlined that: 1) of all methods tested, the DER algorithm gave the most consistent and reproducible results according to the bootstrap and CV analysis; 2) using the DER algorithm accurate estimates could be calculated based on 80-100 particles, corresponding to a typical assay measurement time of 1 min; and 3) the investigated bioaffinity signals contained a large number of outliers (observations that severely deviate from the majority of data) and therefore robust techniques were necessary for the mean signal estimation tasks.

Mesh:

Year:  2006        PMID: 17044407     DOI: 10.1109/titb.2006.875658

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  3 in total

1.  Evaluation of the TPX MRSA assay for the detection of methicillin-resistant Staphylococcus aureus.

Authors:  T Stenholm; A J Hakanen; S Salmenlinna; S Pihlasalo; H Härmä; P E Hänninen; P Huovinen; J Vuopio; P Kotilainen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-02       Impact factor: 3.267

2.  Rapid method for detection of influenza a and B virus antigens by use of a two-photon excitation assay technique and dry-chemistry reagents.

Authors:  Janne O Koskinen; Raija Vainionpää; Niko J Meltola; Jori Soukka; Pekka E Hänninen; Aleksi E Soini
Journal:  J Clin Microbiol       Date:  2007-09-12       Impact factor: 5.948

3.  Methicillin-resistant Staphylococcus aureus screening by online immunometric monitoring of bacterial growth under selective pressure.

Authors:  Teppo Stenholm; Antti J Hakanen; Jonne Vaarno; Sari Pihlasalo; Perttu Terho; Pekka E Hänninen; Jaana Vuopio-Varkila; Pentti Huovinen; Pirkko Kotilainen
Journal:  Antimicrob Agents Chemother       Date:  2009-09-14       Impact factor: 5.191