AIM: The Cox-Maze procedure was introduced nearly two decades ago for the surgical treatment of atrial fibrillation (AF). Recently, our group has replaced most of the incisions of the Cox-Maze procedure with bipolar radiofrequency (RF) ablations (Cox-Maze IV procedure). The purpose of this study was to examine our midterm results with the Cox-Maze procedure using bipolar RF ablation. METHODS: From January 2002 to October 2005, 100 consecutive patients underwent a modified Cox-Maze procedure with bipolar RF ablation for AF; 32 were lone operations, and 68 were concomitant procedures. Follow-up was performed at 1, 3, 6, and 12 months, and then annually thereafter. Heart rhythm was confirmed by electrocardiography. RESULTS: The mean age of patients was 62+/-13 years; 57% were male. Duration of AF was 6.3+/-7.6 years (0.1 to 40 years), 59% had paroxysmal AF, and 34% had permanent AF. Follow-up was complete for all patients with a mean follow-up of 13+/-10 months. At 12-month follow-up, 91% (49/54) of patients were free of AF. Cross-clamp time in the lone Cox-Maze IV procedure patients was 42+/-15 minutes, while it was 101+/-29 minutes for the Cox-Maze IV with a concomitant procedure (compared to 93+/-34 minutes and 122+/-37 minutes for the traditional procedure, P<0.05). There were four operative deaths. CONCLUSIONS: The Cox-Maze IV procedure had good mid-term efficacy. The use of bipolar RF energy significantly decreased operative time and simplified the procedure compared to the traditional Cox-Maze procedure, potentially increasing utilization of the procedure among cardiac surgeons.
AIM: The Cox-Maze procedure was introduced nearly two decades ago for the surgical treatment of atrial fibrillation (AF). Recently, our group has replaced most of the incisions of the Cox-Maze procedure with bipolar radiofrequency (RF) ablations (Cox-Maze IV procedure). The purpose of this study was to examine our midterm results with the Cox-Maze procedure using bipolar RF ablation. METHODS: From January 2002 to October 2005, 100 consecutive patients underwent a modified Cox-Maze procedure with bipolar RF ablation for AF; 32 were lone operations, and 68 were concomitant procedures. Follow-up was performed at 1, 3, 6, and 12 months, and then annually thereafter. Heart rhythm was confirmed by electrocardiography. RESULTS: The mean age of patients was 62+/-13 years; 57% were male. Duration of AF was 6.3+/-7.6 years (0.1 to 40 years), 59% had paroxysmal AF, and 34% had permanent AF. Follow-up was complete for all patients with a mean follow-up of 13+/-10 months. At 12-month follow-up, 91% (49/54) of patients were free of AF. Cross-clamp time in the lone Cox-Maze IV procedure patients was 42+/-15 minutes, while it was 101+/-29 minutes for the Cox-Maze IV with a concomitant procedure (compared to 93+/-34 minutes and 122+/-37 minutes for the traditional procedure, P<0.05). There were four operative deaths. CONCLUSIONS: The Cox-Maze IV procedure had good mid-term efficacy. The use of bipolar RF energy significantly decreased operative time and simplified the procedure compared to the traditional Cox-Maze procedure, potentially increasing utilization of the procedure among cardiac surgeons.
Authors: Timo Weimar; Stefano Schena; Marci S Bailey; Hersh S Maniar; Richard B Schuessler; James L Cox; Ralph J Damiano Journal: Circ Arrhythm Electrophysiol Date: 2011-11-17
Authors: Rochus K Voeller; Andreas Zierer; Shelly C Lall; Shun-ichiro Sakamoto; Richard B Schuessler; Ralph J Damiano Journal: J Thorac Cardiovasc Surg Date: 2010-02-01 Impact factor: 5.209
Authors: Rochus K Voeller; Andreas Zierer; Shelly C Lall; Shun-ichiro Sakamoto; Nai-Lun Chang; Richard B Schuessler; Marc R Moon; Ralph J Damiano Journal: J Thorac Cardiovasc Surg Date: 2008-09-06 Impact factor: 5.209
Authors: Camilla Skals Engelsgaard; Kenneth Bruun Pedersen; Lars Peter Riber; Peter Appel Pallesen; Axel Brandes Journal: Int J Cardiol Heart Vasc Date: 2018-04-13