Literature DB >> 17042569

Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay.

Yunling Bai1, Chee Guan Koh, Megan Boreman, Yi-Je Juang, I-Ching Tang, L James Lee, Shang-Tian Yang.   

Abstract

A novel surface treatment method using poly(ethyleneimine) (PEI), an amine-bearing polymer, was developed to enhance antibody binding on the poly(methyl methacrylate) (PMMA) microfluidic immunoassay device. By treating the PMMA surface of the microchannel on the microfluidic device with PEI, 10 times more active antibodies can be bound to the microchannel surface as compared to those without treatment or treated with the small amine-bearing molecule, hexamethylenediamine (HMD). Consequently, PEI surface modification greatly improved the immunoassay performance of the microfluidic device, making it more sensitive and reliable in the detection of IgG. The improvement can be attributed to the spacer effect as well as the functional amine groups provided by the polymeric PEI molecules. Due to the smaller dimensions (140x125 microm) of the microchannel, the time required for antibody diffusion and adsorption onto the microchannel surface was reduced to only several minutes, which was 10 times faster than the similar process carried out in 96-well plates. The microchip also had a wider detection dynamic range, from 5 to 1000 ng/mL, as compared to that of the microtiter plate (from 2 to 100 ng/mL). With the PEI surface modification, PMMA-based microchips can be effectively used for enzyme linked immunosorbent assays (ELISA) with a similar detection limit, but much less reagent consumption and shorter assay time as compared to the conventional 96-well plate.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17042569     DOI: 10.1021/la061123l

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  19 in total

Review 1.  Protein immobilization techniques for microfluidic assays.

Authors:  Dohyun Kim; Amy E Herr
Journal:  Biomicrofluidics       Date:  2013-07-30       Impact factor: 2.800

2.  Design and testing of a microfluidic biochip for cytokine enzyme-linked immunosorbent assay.

Authors:  Hongyan He; Yuan Yuan; Weixiong Wang; Nan-Rong Chiou; Arthur J Epstein; L James Lee
Journal:  Biomicrofluidics       Date:  2009-04-13       Impact factor: 2.800

Review 3.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

4.  Antibody Conjugate Assembly on Ultrasound-Confined Microcarrier Particles.

Authors:  Michael M Binkley; Mingyang Cui; Mikhail Y Berezin; J Mark Meacham
Journal:  ACS Biomater Sci Eng       Date:  2020-10-09

5.  Evaluation of disposable microfluidic chip design for automated and fast Immunoassays.

Authors:  Guochun Wang; Champak Das; Bradley Ledden; Qian Sun; Chien Nguyen; Sai Kumar
Journal:  Biomicrofluidics       Date:  2017-02-22       Impact factor: 2.800

Review 6.  Flexible fabrication and applications of polymer nanochannels and nanoslits.

Authors:  Rattikan Chantiwas; Sunggook Park; Steven A Soper; Byoung Choul Kim; Shuichi Takayama; Vijaya Sunkara; Hyundoo Hwang; Yoon-Kyoung Cho
Journal:  Chem Soc Rev       Date:  2011-03-25       Impact factor: 54.564

Review 7.  Recent advances in microfluidic sample preparation and separation techniques for molecular biomarker analysis: A critical review.

Authors:  Mukul Sonker; Vishal Sahore; Adam T Woolley
Journal:  Anal Chim Acta       Date:  2017-07-24       Impact factor: 6.558

8.  Electrophoretic separations in poly(dimethylsiloxane) microchips using a mixture of ionic and zwitterionic surfactants.

Authors:  Qian Guan; Scott D Noblitt; Charles S Henry
Journal:  Electrophoresis       Date:  2012-01       Impact factor: 3.535

9.  Internally calibrated quantification of protein analytes in human serum by fluorescence immunoassays in disposable elastomeric microfluidic devices.

Authors:  Emil P Kartalov; David H Lin; David T Lee; William F Anderson; Clive R Taylor; Axel Scherer
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

10.  Internally calibrated quantification of VEGF in human plasma by fluorescence immunoassays in disposable elastomeric microfluidic devices.

Authors:  David H Lin; Clive R Taylor; W French Anderson; Axel Scherer; Emil P Kartalov
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-08-29       Impact factor: 3.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.