Literature DB >> 17042175

Validation of liquid chromatography and liquid chromatography/tandem mass spectrometry methods for the determination of etoricoxib in pharmaceutical formulations.

Liberato Brum1, Marcio Fronza, Danieli Catia Ceni, Thiago Barth, Sergio Luiz Dalmora.   

Abstract

Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17042175

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  2 in total

Review 1.  Clinical pharmacokinetic and pharmacodynamic profile of etoricoxib.

Authors:  Jody K Takemoto; Jonathan K Reynolds; Connie M Remsberg; Karina R Vega-Villa; Neal M Davies
Journal:  Clin Pharmacokinet       Date:  2008       Impact factor: 6.447

2.  A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations.

Authors:  Shipra Singh; Amrita Mishra; Anurag Verma; Ashoke K Ghosh; Arun K Mishra
Journal:  J Adv Pharm Technol Res       Date:  2012-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.